QSG_F670_363.00_EN_01_2021-02-09
27/42
Direct mode
– Sealed part test option
Pressure from 0 to 500 kPa (72.5 PSI).
This configuration can be used for test of small test part volumes.
Protect volumes and pipes from air blowing and temperatures variations.
Connection
Option / description
Air supply to
1
Connection of the air supply to the filter input (0.6 MPa(87 PSI))
Vacuum to
2
Connection to the vacuum (option)
3
to
4
Connection of the reference output to the reference part
5
to
6
Connection of the pressurization output to a transfer volume
6
7
to
9
Connection of the test output to the bell
9
including the part under test
8