QSG_F670_363.00_EN_01_2021-02-09
26/42
Indirect mode
This configuration is used for indirect mode at maximum pressure of 1 MPa (145 PSI).
Connection
Option / description
Regulator air
supply to
1
Connection of the regulator air supply to the filter input (1.2 MPa (174 PSI))
Air supply to
2
Connection of the air supply (0.6 MPa (87 PSI))
Vacuum to
3
Connection to the vacuum (option)
4
to ATM
Output to be left to the atmosphere to exhaust the bell
5
to
7
Connection of the test output to the bell secured by a security valve
6
8
to
9
Connection of the regulator output to the part under test
10
to ATM
Output to be left to the atmosphere to exhaust the part under test