• Step 2: Watch for a Maintenance message displayed on FP5 after a few seconds.
• Step 3: Quickly press the validation key (see Section 4.2, “ Front Panel ”) to enter the Maintenance menu.
Available options are:
• Continue: Exit the maintenance menu and continue booting normally.
• Reset Config: Erase all service configuration parameters.
The "Reset Config" function is useful when a newly installed version crashes on boot because of an incompatibility
with the previous settings.
Only the service configuration parameters will be lost. The firmware version and system parameters will stay the same.
This is the first thing to try.
• Backup System: Performs a backup of the current firmware version. Same function as Firmware Backup described
in Section 6.2, “ Firmware management ”.
• Restore System: Restores a previously saved system version.
If the current system version gets corrupted for some reason, restoring an older version can make the system usable
again allowing you to take control of the web interface.
• Restore Factory: Restores the system to its factory version.
It will reset everything including: services configuration settings, firmware version and system parameters.