CM5000 User Manual
UM-CM5000-FW3.5.2.0-REV0.0
2019-07-08
www.ateme.com
Page 41
Figure 4.6. Web Interface - Remuxer Tab
• [GC1]: Button used to load a preset into the web GUI editor. The preset can be loaded from a file, from slots stored
on the CM5000 or from a preset using factory settings. This action does not disrupt nor reconfigure the remuxer.
• [GC2]: Button used to save the content of the web GUI editor to a file or to a slot stored on the CM5000.
• [GC3]: Button used to discard non applied changes done in the web GUI editor. After this action, the web GUI
editor will show the settings that are being used by the remuxer.
• [GC4]: Button used to apply changes done in the web GUI editor. After this action, the remuxer will use the new
settings.
Table 4.7. Web Interface - Remuxer Tab Settings
Global settings
Settings that apply to the whole transport stream (e.g. TS bitrate, compliance)
Output settings
Settings that apply to the output (e.g. ASI, IP)
Input TS settings
Settings that apply to the input Transport Stream (e.g. sources, delay)
Note
You can safely navigate away from this tab without losing your changes even if some of them are not
yet applied.
Note
Not yet applied changes are visually identified by a light orange outline.