Programming Procedures
■
T316 Timer – times the delay in network response when the system
sends a restart message to clear a B-channel
NOTE:
If you enter an invalid timer value, the number you enter is truncated to the
closest valid value. For example, if you enter 45 for a counter that ranges
from 0-30, 4 is recorded.
The following table shows the factory setting for each timer and counter and the
valid range for each threshold.
Entering Programming
Console: Select Menu
→
Sys Program
→
Exit
PC/SPM: Type
SPM
→
press any key
→
[F1]
→
[F5]
Exiting Without Changes
To exit from any screen without making changes, select
Exit
on the console or
press
[F5]
on the PC before saving your entry or menu selection.
Summary Timers and Counters
Programmable by
System manager
Mode
All
Idle Condition
Not required
Planning Form
Form 3b, Incoming Trunks — DS1 Connectivity (100D
Module)
Factory Setting
See Table 3-2
Table 3-2. Timers and Counters
Timer/Counter Setting
Factory Setting
Valid Range
T200 Timer
T203 Timer
N200 Counter
N201 Counter
K Counter
T303 Timer
T305 Timer
T308 Timer
T309 Timer
T310 Timer
T313 Timer
T316 Timer
Maximum response time
Maximum time
Maximum transmissions
Maximum octets
Maximum outstanding
l-frames
Setup timeout
Disconnect timeout
Release timeout
Signal loss
Call Proc. timeout
Connect timeout
Restart timeout
1 second
30 seconds
3 transmissions
260 octets
7 frames
4 seconds
4 seconds
4 seconds
90 seconds
10 seconds
4 seconds
120 seconds
1000 - 3000 ms
1-60 seconds
1 – 5 transmissions
16-260 octets
1-15 frames
4-12 seconds
4-30 seconds
4-12 seconds
30-120 seconds
2-10 seconds
4-12 seconds
30-120 seconds
3-202
Timers and Counters
Summary of Contents for MERLIN LEGEND Release 2.0 Analog Multiline Telephone
Page 6: ...Contents iv Table of Contents ...
Page 715: ...A 2 Menu Hierarchy ...
Page 719: ...LED Displays B 4 Console LED Status ...
Page 720: ...LED Displays Table B 2 Continued Console LED Status B 5 ...
Page 725: ...General Feature Use and Telephone Programming Table C 1 Continued F e a t u r e T a b l e C 5 ...
Page 726: ...General Feature Use and Telephone Programming Table C 1 Continued C 6 Feature Table ...
Page 727: ...General Feature Use and Telephone Programming Table C 1 Continued Feature Table C 7 ...
Page 734: ...Button Diagrams Figure D 1 MLX Telephone Button Diagram Hybrid PBX Mode D 2 Button Diagrams ...