52
About Edge Operations
During edge operations the function in question is toggled at the falling edge of the control signal.
Ex.) SDI_A/SDI_B
About Bi-Edge Operations
During bi-edge operations, the setting value changes at each rising edge and falling edge of the control
signal.
Ex.) Switches SDI_A/SDI_B
Precautions
• During edge operations, be sure to input an active pulse having a cycle of at lease 50 ms.
• When using a remote controller, set the ENABLE pin to make. For details, see “2.2
WM-3209/WM-3209-L Rear Panel and Names of Parts.”
The function is toggled at
this instant
SDI_A
SDI_B
SDI_A
The function is toggled at
this instant
SDI-A
SDI-B
SDI-A
Setting switched at
this time
Setting switched at
this time
The setting value is changed if a switching instruction arrives due to operation
of switches on the front panel.