6-36
Troubleshooting
3
With the cam in hand, adjust printhead pressure by turning the
thumbwheels as required to maximize the clarity and detail of the label.
Turn thumbwheels counterclockwise to raise them, decrease pressure on
the printhead, and lighten the image. Turn thumbwheels clockwise to
lower them, increase pressure on the selected printhead, and darken the
image.
4
Slide the cam back in place. Make sure the silver clip is securely seated.
5
Flip the printhead cam closed to restore pressure to the printhead.
If after adjusting printhead pressure, print quality is not improved, check
other settings that affect print quality, such as heat intensity.