To replace the gap top-of-form (TOF) sensor:
1
Follow the procedure for removing the media sensor assembly noted
earlier in the manual.
2
Remove the four Phillips screws from media sensor bracket. These
screws are flat-headed and fit into the recessed holes of the bracket. Then
remove the bracket.
3
Slide the red plastic sensor molding away from the two sensor guides.
4
Remove the top and bottom covers from the red plastic sensor molding.
Then remove the wire harness contained inside. These wires are held in
place by double-sided tape.
5
Replace the wire harness. The emitter and detector ends of the harness
each have a small round bump. These two bumps should face inward
through two small corresponding holes in the molding.