5.2.6
Secure the Cable
For safety reasons secure the base station cable to a convenient point at about 30 cm from
the base station.
If for some reason the base station drops, it is secured by the cable.
5.2.7
Pinning
1
Cut the cable to the correct length and connect the cable to a RJ45 modular jack.
2
For information on the pinning of the data jack see the following:
• IPBS,
Pin the IPBS Cable
on page 32.
• BS3x0 and DB1,
Pin the BS3x0/DB1 Cable
on page 33.
Do
not
plug the connector in the base station yet!
Note:
Since the distance between the base station and the wall is limited, a RJ45 modular
jack without cable retention must be used.
Pin the IPBS Cable
Figure 9.
RJ45
modular jack
Tx
Tx
Rx
Pwr
Pwr
Rx
Pwr
Pwr
Pwr = Power pairs
Rx = Reciever data pair
Tx = Transmitter data pair
014
1
5
4
3
2
6
7
8
Figure 12. Connector pinning of the LAN/PoE connector, power feed over the spare
cable pairs.
Figure 10.
RJ45
modular jack
Tx/Pwr
Tx/Pwr
Rx/Pwr
Spare
Spare
Rx/Pwr
Spare
Spare
NC
=
Not Connected
Rx/Pwr
=
Reciever & power pair
Tx/Pwr
=
Transmitter & power pair
015
1
5
4
3
2
6
7
8
Figure 13. Connector pinning of the LAN/PoE connector, power feed over the Rx/Tx
data cable pairs.