TD 92579EN
15 February 2012 / Ver. H
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway (software version 5.0.x)
10
2.3
IPBL
The following versions of the IPBL are available:
• IPBL IP-DECT Gateway VAC/VDC (for 110/230 VAC or 48 VDC)
• IPBL IP-DECT Gateway VDC (for 48 VDC)
2.3.1
Overview
Figure 4. Overview of the IPBL
2.3.2
Power Supply
The power supply are located at the rear of the IPBL. The IPBL can be powered using the
following alternatives:
• 110/230 VAC (
only IPBL IP-DECT Gateway VAC/VDC
)
• 48 VDC
Note:
For more information, see
6.3
Power the IPBL
on page 40.
Software
The software in the IPBL can be updated by downloading new software without
disconnecting the equipment. The new software is stored in flash memory. See
8.18
Update
on page 130 for information.
Pos.
Name
Function
1
Reset
Resets the IPBL, see
8.23
Reset Using the Reset Button
on
page 138 for more information.
2
Status LED
Indicates the status on the IPBL.
3
Lan
10BASE-T/100BASE-T Ethernet interface.
LAN1 port must be used in the IP-DECT system (LAN2 port
is for administration only).
4
Synchronization
Sync ring in and sync ring out interfaces.
5
Reference
Reference sync in and reference sync out interfaces.
6
Base station 01-16
ISDN U
PN
DECT base station interfaces.
lan synchronization reference
1 2 ring in ring out in out
base station 01 02 03 04 05 06 07 08
09 10 11 12 13 14 15 16
006
1 2
3
4
5
6