(Transducer Configuration, continued)
int#
Input Type
infs#
Input Full Scale
0
Volts
0 to 9999.9
1
Amps
2
Phase
inll#
Input Lower Limit
3
Frequency
0 to 9999.9
4
Power
5
Vars
dco#
DC Output
6
Volt Amps
0
Volts
7
Power Factor
1
Millamperes
ofs#
Output Full Scale (DC)
di#
Display input as:
0 to
±
10 VDC or
0
Measured quantity
0 to
±
100 mAdc
1
% full scale
oll#
Output Lower Limit(DC)
do#
Display Output as:
0 to
±
10 Vdc or
0
Measured Quantity
0 to
±
100 mAdc
1
% full scale
2
% error
A.3.8
Daylight Saving Time, Set (DAY)
Command:
#DAY
Sets the daylight saving time mode for the real-time clock.
#
Designation
0
Daylight saving time OFF
1
Daylight saving time ON; adds one hour to the standard
time.
2
AUTO daylight saving time; automatically adjusts the
time for USA standard daylight saving time (2:00 AM on
the first Sunday in April to 2:00 AM on the last Sunday
in October).
A.3.9
Display Dump, ASCII (DDA)
Command:
DDA
Screen dump in ASCII format
Response: Returns up to 8 lines of 40 ASCII characters, each correspond-
ing to the front panel display presentation; Omits blank lines and converts
graphics characters to standard ASCII representation.
110
Summary of Contents for 931A
Page 6: ...vi ...
Page 12: ...xii ...
Page 14: ...xiv ...
Page 16: ...xvi ...
Page 52: ...SOURCE LOAD B A C N Figure 3 12 3 Phase 4 Wire 3 Element Connections 36 ...
Page 90: ...Iout I1 V1 V2 V3 I2 I3 Figure 3 17 3 Phase 4 Wire 3 Element Transducer Test 74 ...
Page 114: ...98 ...
Page 120: ...104 ...
Page 142: ...126 ...