24
English
9.5
Display (delivery / programming)
The display described below refers to the main screen: the symbols indicate the data which can
be displayed during treatment;
refer to par. 9.6 for the explanation of the other symbols displayed during programming.
A
Number of fi eld
being treated
B
Distribution value:
the value is to the left of the
symbol and displays during treatment
C
Foam marker active side
D
Active operation indicator:
• Auto =
the computer is operating in automatic mode
• Man =
ithe computer is operating in manual mode
E
Speed:
the value is to the left of the symbol
F
Nozzle / working program
in use during
treatment
G
Space covered
You can scroll through these
parameters by pressing key
: the value is displayed to
the left of the corresponding
symbol
H
Time of operation
I
Treated area
J
Tank level
You can scroll through these
parameters by pressing key
: the value is displayed to
the left of the corresponding
symbol
K
Liquid distributed
L
Battery voltage
M
Flow rate
You can scroll through these
parameters by pressing key
: the value is displayed to
the left of the corresponding
symbol
N
Pressure
O
Rpm
Tab. 21
CONTINUES