Pump Protector (Menu 101.0)
This parameter enables/disables the "Pump Protector" sensor signal, which warns of damage to
the pump membrane.
• Alarm DISABLED: corresponds to programming option "
"
• Alarm ENABLED: corresponds to programming option "
"
• Access programming as described in
par. 9.9 - Access to advanced program-
ming
1) Press in sequence to scroll through the
parameters in the Advanced Menu, and
select Menu 101.0
2) Press in sequence to enable the Pump
Protector alarm
During data modification:
A) Press to confirm the new value
B) Press to exit without modifying the
value
If you have enabled the Pump Protector alarm, make sure to disable the parameter
on the input used to connect the Pump Protector sensor (Rpm or fi ller fl ow meter).
Refer to paragraphs 9.19.1 - Filler fl ow meter and 9.22 – Rpm sensor.
CAUTION:
only use the secondary input (T) if the input marked X is occupied by another sen-
sor.
Do not use the secondary input (T) if no sensor is connected to the X input, as the
computer will not detect the Pump Protector in this confi guration.