![Aquasafe WSL50 Pro Instruction Manual Download Page 87](http://html.mh-extra.com/html/aquasafe/wsl50-pro/wsl50-pro_instruction-manual_2960691087.webp)
User Calibration
If a test method is user calibrated, the method name is displayed inverse.
Procedure:
-
Prepare a standard of known concentration and use this standard instead
of the sample according to the test procedure.
-
It is recommended to use well known standard which hare formulated
according to DIN EN, ASTM or other international norms or to use the
certified standards which are commercially available.
-
After measuring this standard solution it is possible to change the
displayed results to the required value.
-
If a method uses a mathematic equation for the calculation of the results,
it is only possible to calibrate the basic tests since all the other tests use
the same polynomial.
-
The same applies for some test procedures which use a polynomial from
another test procedure.
Return to factory calibration:
If the user calibration has deleted the factory calibration is automatically activated.
Remarks:
The ‘fluoride’ method cannot be calibrated with mode 45 since the test requires a
calibration related to the batch of liquid reagent (SPADNS) (mode 40, chapter
‘Fluoride Method 170’, see above).
No.
Method
Recommended range for user calibration
35
Alkalinity- p
100-300 ml/l CaCO
3
30
Alkalinity-total
50-150 mg/l CaCO
3
31
Alkalinity-total HR
50-300 mg/l CaCO
3
40
Aluminium
0.1-0.2 mg/l Al
60
Ammonium
0.3-0.5 mg/l N
85
Boron
1 mg/l B
80
Bromine
Calibration with basic test 100 chlorine free
90
Chloride
10-20 mg/l Cl-
100
Chlorine
0.5-1.5 mg/l Cl
103
Chlorine HR
0.5-6 mg/l Cl
120
Chlorine dioxide
Calibration with basic test 100 chlorine free
125
Chromium
1 mg/l Cr
130
COD LR
100 mg/l O
2
131
COD MR
500 mg/l O
2
132
COD HR
5 g/l O
2
= 5000 mg/l O
2
204
Colour Pt-Co
Operating range
150
Copper
0.5-1.5 mg/l Cu
160
CyA-TEST
30-60 mg/l CyA
Summary of Contents for WSL50 Pro
Page 1: ...AquaSafe WSL50 Pro Water Safety Laboratory Instruction Manual ...
Page 4: ...Section 2 Kit Contents c c c c b a e f d ...
Page 7: ...Section 3 ...
Page 8: ...AquaSafe Micro biological Incubator Instruction Manual ...
Page 10: ...6 0 Guarantee and Assistance 32 ...
Page 12: ......
Page 16: ......
Page 21: ......
Page 33: ...Section 4 ...
Page 34: ...AquaSafe Membrane Filtration Instruction Manual ...
Page 50: ...Section 5 HydroTest Photometer HT1000 ...
Page 86: ......
Page 136: ......
Page 142: ...HydroCheck HC1000 Multi Parameter Electrochemical Water Tester Instruction Manual ...
Page 193: ...NOTES ...