SEMIAUTOMATIC MODE WITH STOP
(
3
)
Starting with the gates closed:
START pulse the wings open and the gates stays stopped in the open position another START pulse will close
the gate.
The START pulse during opening stops the wings another START pulse will close the wings.
The START pulse during closing opens the wings.
STEP-BY-STEP MODE
(
4
)
Starting with the gates closed:
START pulse
the wings open and the gates stays stopped in the open position another START pulse will close
the gate.
The START pulse during opening stops the wings another START pulse will close the wings.
The START pulse during closing stops the wings another START pulse opens the wings.
MANNED MODE
(
5
)
Manned mode requires the presence of an operator to operate and stop the gate by pressing and releasing the START
button.
Repeatedly pressing the START button causes alternate opening and closing.
Starting with the gate closed, the complete operating cycle is as follows:
START pulse
the gate opens and moves until START is pressed and held or until the gate is fully open.
safety device triggered during opening movement stops until the signal is disabled (or the button is released).
next START pulse the gate moves in the opposite direction (CLOSES) and continues to move until START is pressed
and held or until the gate is fully closed.
photocell triggered during closing movement stops until the signal is disabled (or the button is released).
TIMER MODE
(
6
)
Timer mode ensures the gate remains open when the START pulse is pressed and held. The gate closes when the
START button is released.
Operating logic
l
egend:
locks
1
:
locks and inhibits signals until a START command
locks
2
:
locks until a START to close
locks
3
:
locks until a START command to close ignoring pause time
locks
4
:
locks as long as the photocell is covered, ignoring pause time
locks
5
:
if the START command is given within the
fi
rst 3 seconds of the opening pause, will lock until a new START command to close
is given
locks
6
:
locks if the photocell is covered and then closes
locks
7
:
locks as long as the photocell is covered; when the photocell is uncovered will complete the movement
locks
8
:
LOCKS until a new START command is given and then opens
locks
9
:
the START command is inhibited as long as the photocell is covered then closes
closes
1
:
closes ignoring the pause time
re-opens
1
:
reopens slowly
re-opens
2
:
LOCKS until a new
START
command is given and then opens slowly