English
J1
RS232 serial connector / Urmet interface connector
J3
removable terminal board - power for two 24 V DC motors - 2-wire cables with minimum section of 1.5 mm
2
J4
13 pin removable terminal board - connections for control and accessory inputs
1-2 Electric lock -
12 V AC output with maximum connectable load of 15 W controlling the electric lock for
approx. 1.5 seconds in the opening stage.
3-4
Flashing LED, 24 V DC - two-wire cables with min. section 1 mm
2
. DO NOT use other types of
fl
ashing light.
5-4
Warning light - 24 V DC output with maximum load of 3 W for gate warning light.
6-10
Pedestrian opening start (N/O).
7-10
24 V power supply for ACCESSORIES.
8-10
Opening safety device (safety contact N/C).
9-10
Closing photocells input (N/C safety contact)
11-12
STOP (N/C safety contact) to stop wing.
13-12 START (N/O) starts wing opening and closing
.
J6
removable connector for primary transformer (230 V AC)
J7
removable connector for optional battery recharging card
to use two 12 V 1.9 A/h or 1.3 A/h batteries (not supplied with the unit)
J9
removable terminal board - connections to encoder for motor 2
J10
removable terminal board - connections to encoder for motor 1
J12
connector for integrated receiver memory module
M1
removable terminal board - 230 V AC phase-neutral-earth connection
DL1
power supply connected warning light
BATT
24 V DC battery connection
JRX
connector for integrated receiver
CN1
10-pin connector for PL-ECO receiver
CN2
3-pin
Aprimatic
connector for accessories; connection for radio card compatible with UNICO receiver - GSM
- decoder access control -
CN3
terminal board - antenna for integrated receiver
FS1
FS2
2 faston connectors for secondary transformer (21 V AC)
F1
fuse for primary transformer protection -
F2
fuse for external accessory protection (24 V DC) -
F3
fuse for electronic circuit protection -
DS1
DS2
DS3
DS4
four LED display units (7 segments and one dot) to display parameters and parameter values
3 programming buttons:
YELLOW ESC
to exit the current process (and can be used to show the connections on the display) (and can be used
before self-teach process to drive motor 1 when manned)
BLUE
scroll
to scroll through the options available (and can be used before self-teach process to drive motor 2
when manned)
RED
OK
to access basic programming and to con
fi
rm the option displayed
2.4.2 UNIT COMPONENTS AND CONNECTIONS
3.1
SYSTEM START-UP: SELF-TEACH
When all the connections have been completed you must run the self-teach cycle before putting the
system into service. The entire procedure must be completed otherwise the automation will not work.
During the self-teach procedure the unit acquires or updates the following installation data to ensure correct
functioning:
stroke span
;
wing
opening/closing direction;
number of operators
connected
;
profi les of the current
absorbed by the operators;
presence of incremental
encoders
fi
tted on motors;
Electrical connections