Main features
●
Self-teach function for number of wings, stroke span, motor polarity, electric lock installation
●
Electronic speed adjustment - Current limits automatically adjusted in accordance with temperature and friction
variations
●
Obstacle recognition (reaction based on settings made e.g. block wing, invert drive, etc.)
●
Slowing on approach to opening/closing stop
●
Pedestrian opening available (on one wing)
●
Manned functioning available (by setting the relevant parameter) with safety device overridden
●
Step-by-step functioning
●
Non-reversible motors available when wings closed (enable short circuit parameter)
●
Emergency procedure when mains power restored
●
Programming data saved in
fl
ash memory
●
Data saved in EEPROM memory (gate status, spatial and angular position off wings) in the event of mains power
or battery failure
●
Remote control devices can be installed e.g.: PL-ECO receiver, Unico Receiver, DEC/A (tag decoder and keypad),
GSM
●
GSM cycle counter output (500 ms pulse)
●
Functioning cycle counter for routine maintenance
Technical specifi cations
Power supply voltage for accessories
230 V AC (±10 %)
Frequency
50 Hz
Motor power supply
24 V DC
Accessory power supply
800 mA
Power consumption (no load)
3 W
Power consumption (Max.)
250 W
(with 2 motors and accessories connected up and
operating)
Operating temperature
-20°C +70°C
Storage temperature
-20°C +85°C
Relative humidity
<95% non condensing
Protection class
IP44 (only with IP44 housing)
Primary transformer protection fuse (
F1
)
3.15 A fast blow
External accessories protection fuse (24 V DC) (
F2
)
1 A fast blow
Electronic circuit protection fuse (
F3
)
8 A fast blow
Toroidal power transformer
250 V AC
1.1
PRODUCT DESCRIPTION - TECHNICAL
SPECIFICATIONS
R1-24
- electronic unit
fi
tted with a microprocessor to drive
1 or 2 motors with encoder. The motors are powered at 24
V DC and up to a maximum overall power of 250 Watt.
The unit acquires the data of the installed system by
performing a self-teach cycle to set the functioning
parameters.
The programming of functioning parameters can be
modified (digital adjustments) to ensure optimum
automation performance in accordance with the type of
equipment controlled.
The R1-24 can be supplied with a radio receiver already
programmed on the unit.
Features of the unit
Fig. 1
R1-24 card
-
+
DL1
8 8 8 8
21 V AC
L N
1
3
6 7
10 11 12
2
4
5
8 9
13
M1
M2
F1
F2
F3
4
2
3
1
4
2
3
1
J10
J9
J3
J4
M1
BATT
CN1
CN2
J1
DS1 DS2 DS3 DS4
J7
FS1 FS2
J6
JRX
FS3
FS5
FS4
J12
CN3
YELLOW