CONDENSATION BOILER
AQUAKOND AKY
24
code HC0048.01GB ed.B-1406
AKY
1
R
20
F9
R
56
C26
Q1
R
8
C
N
15
R
10
4
R22
R
87
C
49
F5
D6
C50
C32
R
39
U15
C41
Q
2
C
N
11
R
48
U
1
C
N
12
C28
R
61
R24
U
8
C
21
F3
R
3
R50
R27
F4
U
2
R
16
R1
U
4
R29
CN04
C42
R
44
R
66
F6
R
52
TP1
R83
R4
R
73
R101
C54
C55
C18
R
17
U9
R
65
R2
R91
C35
R
97
C
6
O
P
1
L1
D
Z1
C
1
T2
D
11
D16
C12
R90
C34
R
10
3
F1
D7
R
37
R
7
R
18
R
74
CN13
D17
R5
C37
R99
C31
C
2
SW1
R94
C
52
R34
U3
F8
C56
R89
C
14
R
25
F2
R
10
6
R77
R43
C
27
R49
R
10
R
58
C40
C
20
C
8
Q
5
R
45
R
62
RL2
C
22
R
64
D3
C
23
CN01
LC1
R
32
RL1
C51
U
11
LC
6
C11
R70
R41
R40
D9
D1
R35
R
11
0
R
42
R
31
R59
R96
TS
1
R38
D5
D
20
Q
3
R
23
D
2
R
55
R
26
CN02
D10
C29
R
10
0
C15
C33
D13
R
19
R78
R108
R102
R76
R79
D8
C
43
TS
2
C
5
C
10
R
9
U
14
LC
5
LC
2
C38
C
17
Q
6
V
R
1
C
N
08
C
3
R
71
R95
R
72
R
12
T1
C36
C53
R
10
7
U5
D4
R82
XT1
C
48
F7
R
88
C30
R
28
R
14
C39
R63
R54
R
11
U
13
R
53
C46
RR1
C16
C
45
R
10
9
R
13
C
44
CN06
LC3
J1
U
10
R30
R
57
R
15
R
21
R36
C
N
14
R
98
R86
R
60
C
9
D
14
D19
D
12
R
69
CN07
R84
C
7
D15
D
21
R93
RD1
C47
R
10
5
R
81
LC4
R
47
R
67
R92
R51
R
68
Q
4
R85
R75
C
N
05
C
25
U
12
CN03
C
13
R6
R
80
R33
C
4
D
18
LF
N
+5
V
B3
G
N
D
+5
V
B2
G
N
D
B1
G
N
D
NTC3
NTC3
N
NTC2
NTC2
NTC1
NTC1
D-
D+
GND
+12V
+2
8V
H
AL
L
L1
PW
M
G
ND
ID
2
ID
C
2
ID
3
ID
C
4
ID
4
ID
C
5
ID
5
ID
C
6
N
ID
6
+2
8V
Y2
Y1
G
ND
Q
2
C
O
M
N
.C
.
N
.O
.
N
N
L
GND
7Vdc
24Vac
24Vdc
CLK
DAT
N
C
ID
C1
ID
1
LB
W
V+ G
N
D
A+ B- N
TC
N
TC
I1 I2 I3
A+ B- GND
1
SW1
2
3
4
5
6
7
8
HC0047 C2 010
CPU-SMART
Switch for boiler address
MOD_BUS Connection
Respect polarity
SmartControl supply voltage
Respect polarity
Binary code is used for setting the
address. Codes are are following:
1st=1; 2nd=2; 3rd=4; 4th=8; 5th=16;
6th=32.
Therefore, to configure address 13,
move to ON switches 4th+3rd+1st.
Corresponding address is
8+4+1=13.
To change the address, power the
board off and then on.
5.5.3. Smartcontrol remote control connection
Use supplied connector to connect the SmartControl. Wire
cables complying with their polarity.
Connect RS485 network to relevant terminals.
If more boilers are installed, connect terminals D+ and D- to
each other. The network can have a serial or a star topology.
Use a shielded cable with a section of at least 0.4 mm2.
You then need to set correct address for each board.
Ad-
dresses go from 1 to N without gaps. Each board address, if
different from zero, is displayed on LCD screen as Axx, where
xx is the address.
To configure SmartControl, see relevant manual supplied with
the device.
Summary of Contents for AQUAKOND AKY
Page 2: ...CONDENSATION BOILER AQUAKOND AKY 2 code HC0048 01GB ed B 1406 AKY ...
Page 4: ...CONDENSATION BOILER AQUAKOND AKY 4 code HC0048 01GB ed B 1406 AKY 3 7 Approval Certificate ...
Page 5: ...CONDENSATION BOILER AQUAKOND AKY 5 code HC0048 01GB ed B 1406 AKY ...
Page 44: ...CONDENSATION BOILER AQUAKOND AKY 44 code HC0048 01GB ed B 1406 AKY ...