2-27 Frequency Menu (Freq 1/2) with Offset Function
Spectrum Analyzer
2-52
PN: 10580-00349 Rev. H
Spectrum Analyzer MG
Offset Center Freq :
Press the
Freq
main menu key followed by the Offset
Center Freq submenu key and enter the desired frequency using the keypad,
the arrow keys, or the rotary knob. If entering a frequency using the keypad,
the submenu key labels change to GHz, MHz, kHz, and Hz. Press the
appropriate units key. Pressing the
Enter
key has the same effect as the MHz
submenu key. With zero offset, this key differs, refer to
Offset Start Freq:
Press the
Freq
main menu key followed by the
Offset Start Freq submenu key and enter the desired frequency using the
keypad, the arrow keys, or the rotary knob. If a start frequency higher than the
current stop frequency is entered, the stop frequency will be changed to yield
a 10 Hz span.
Offset Stop Freq:
Press the
Freq
main menu key followed by the
Offset Stop Freq submenu key and enter the desired frequency using the
keypad, the arrow keys, or the rotary knob. If a stop frequency lower than the
current start frequency is entered, the start frequency will be changed to yield
a 10 Hz span.
Span:
Press the
Freq
main menu key followed by the Span submenu key
and enter the desired span. Refer to
Signal Standard:
Use the up or down arrow keys or the rotary knob to
highlight a signal standard and press
Enter
to select.
When a signal standard is selected, the center frequency and span for the
first channel of the last segment of the particular standard is automatically
tuned. Other settings, such as channel spacing and integration bandwidth,
are also automatically entered.
Channel #:
Use the up or down arrow keys, the keypad, or the rotary knob to
select a channel number for the selected signal standard. The center of the
channel is tuned to the center of the spectrum analyzer display. The
frequency value is the amount by which the center frequency differs from the
center of the channel.
Step Size & Offset:
Opens the
.
Figure 2-37.
SPA Freq 1/2 with Offset Function Menu
Freq 1/2
Offset Center Freq
## GHz
Offset Start Freq
## GHz
Offset Stop Freq
## GHz
Channel
- -
Signal
Standard
Span
Step Size &
Offset
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com
Summary of Contents for Spectrum Master MS2720T
Page 2: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 5: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 22: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 241: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 264: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 265: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 558: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 800: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1027: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1033: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1034: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1035: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...