2-13 Occupied Bandwidth Measurement
Spectrum Analyzer
2-16
PN: 10580-00349 Rev. H
Spectrum Analyzer MG
Power density to field strength:
An alternate measure of field strength is power density:
P
d
= E
2
/ 120
π
where:
E = field strength in V/m
P
d
= Power density in W/m
2
Power density at a point:
P
d
= P
t
G
t
/ (4
π
r
2
)
where:
P
d
= power density in W/m
P
t
= power transmitted in Watts
G
t
= gain of transmitting antenna
r = distance from the antenna in meters
This equation is only valid in the far field, where electric and magnetic fields are related by
the characteristic impedance of free space.
2-13 Occupied Bandwidth Measurement
Occupied Bandwidth (OBW) is a common measurement performed on radio transmitters.
This measurement calculates the bandwidth containing the total integrated power occupied
in a given signal bandwidth. There are two different methods of calculation depending upon
the technique used to modulate the carrier.
• % Integrated Power Method:
The occupied frequency bandwidth is calculated as the
bandwidth containing the specified percentage of the transmitted power.
• > dBc Method:
The occupied frequency bandwidth is defined as the bandwidth
between the upper and lower frequency points at which the signal level is a desired
number of dB below the peak carrier level.
Required Equipment
•
Test Port Extension Cable, Anritsu part number 15NNF50-1.5C
•
30 dB, 50 Watt, bi-directional, DC –18 GHz, N(m) – N(f), Attenuator, Anritsu
42N50A-30 (required if the power level being measured is > +30 dBm)
Procedure
1.
Using the test port extension cable and the 30 dB, 50 watt, bi-directional attenuator
(if needed) connect the
RF In
port to the appropriate transmitter test port or signal
source.
2.
Press the
Freq
main menu key followed by the
Center Freq
submenu key and enter the
center frequency using the keypad, the arrow keys, or the rotary knob. If entering a
frequency using the keypad, the submenu key labels change to GHz, MHz, kHz,
and Hz. Press the appropriate units key. Pressing the
Enter
key has the same effect as
the MHz submenu key.
3.
If an attenuator was connected in
, then press the
Amplitude
main menu key then
press the
RL Offset
submenu key, enter
30
then select dB
External Loss
to compensate
for the loss in the attenuator.
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com
Summary of Contents for Spectrum Master MS2720T
Page 2: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 5: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 22: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 241: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 264: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 265: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 558: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 800: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1027: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1033: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1034: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...
Page 1035: ...ООО Техэнком Контрольно измерительные приборы и оборудование www tehencom com ...