3.3
Starting Measurement
3-7
3
Measurem
ent
3.3 Starting Measurement
3.3.1 Starting Auto Measurement
Auto measurement is performed as follows:
Fig. 3.3.1-1 Auto measurement start procedure
1.
Check that status is “Ready” and server and client are connected.
For details on server and client Connection refer to Section
2.3.2 (1) "Connection"
2.
Click the “Auto” radio button.
3.
Select the [Use] checkbox of the port pair to measure.
4.
Set the “Repeat” count as necessary.
5.
Click the [Start] button.
Measurement starts.
When measurement ends, the screen returns to the state before
starting measurement.
Notes:
1. During measurement, the [Start] button changes to [Stop]
button. Click the [Stop] button to stop measurement.
2. When user flow is set to “Continuous”, measurement does not
stop automatically. Click the [Stop] button to manually stop
measurement.
For details on user flow settings refer to Section 2.3.1 (3) "User
Flow"