Anritsu MD1230B-26 Operation Manual Download Page 47

2.3

Port Pair Parameters

2-17

2

Sett

ings

Table 2.3.3-1    Parameter setting on the Users tab of the

Node window (PPPoE)

Setting Items and

Parameters

Description

Group # or Server #

 1 to 16

Select the client or server to set with a

number.

Initial value: 1

Client Name or
Server Name

 0 to 255 characters

Specify the name of the client or server with

up to 255 byte.

Type

 Static

 Increment

Select the user ID and password setting

method.
Initial value: Static

[User ID and

Passwords...]

This is displayed when the Type is “Static”.

Set the user ID and password pair in the

User ID & Password & MAC Address dialog

(next page). This dialog can control 128 pairs

for server and 1000 pairs for client.

User ID

 0 to 251 characters

This is displayed when the Type is

“Increment”. Set the start User ID. For

example, when the Type is “Increment” and

the User ID is “User”, values such as

“User0001”, “User0002”, ... are used for

authentication.
Initial value: User

Password

 0 to 251 characters

This is displayed when the Type is

“Increment”. Set the start password. For

example, when password is "Password",

values such as “Password 0001”, “Password

0002”, ... is used for authentication.
Initial value: Password

# of User

 1 to 128

This is displayed for server. Set the number

of Combination(user ID and password) for

authentication.
Initial value: 1

Summary of Contents for MD1230B-26

Page 1: ...ual before attempting to use the equipment Additional safety and warning information is provided within the MD1230B Data Quality Analyzer Operation Manual Please also refer to this document before usi...

Page 2: ...uipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions Ensure that you clea...

Page 3: ...hange depending on whichever is longer This warranty does not cover damage to this software caused by Acts of God natural disasters and misuse or mishandling by the customer In addition this warranty...

Page 4: ...roduct s country of origin for re export from your country Before re exporting the product or manuals please contact us to confirm whether they are export controlled items or not When you dispose of e...

Page 5: ...taneously 2 Copyright 1 Although you are licensed to use this software Anritsu retains the copyright 2 Although you have purchased this software rights other than those specified in this license are n...

Page 6: ...LVD directive of the European Union EU CE marking 1 Product Model Option MD1230B 26 PPPoE 2 Applied Directive and Standards When the MD1230B 26 is installed in the MD1230B the applied directive and st...

Page 7: ...f Australia New Zealand C tick marking 1 Product Model Option MD1230B 26 PPPoE 2 Applied Directive and Standards When the MD1230B 26 is installed in the MD1230B the applied directive and standards of...

Page 8: ...viii...

Page 9: ...f the MD1230B MD1230B Data Quality Analyzer Operation Manual Describes how to use the software that controls the mainframe of the MD1230 family MX123001A Data Quality Analyzer Control Software Operati...

Page 10: ...rations of Decode modules Decode Module Operation Manual Describes basic operations of Tcl Interface Tcl Interface Operation Manual Describes basic operations of Expert Analysis modules Expert Analysi...

Page 11: ...g equipment and software Model Name Product Name Option Name of Corre sponding Application PPPoE MD1230B Data quality analyzer MD1230B 26 In this manual the MD1230B are referred to as main unit The MD...

Page 12: ...Section 2 Settings 2 1 2 1 Setting Items 2 2 2 2 Ports Parameters 2 3 2 3 Port Pair Parameters 2 6 2 4 Saving and Loading Settings 2 32 Section 3 Measurement 3 1 3 1 Measurement 3 2 3 2 Control Bar 3...

Page 13: ...V 1 2 3 4 Appendix...

Page 14: ...VI...

Page 15: ...ection summarizes this option 1 1 Product Overview 1 2 1 2 Features 1 4 1 3 Usage Restrictions 1 5 1 4 Starting Application 1 6 1 5 Using Application 1 10 1 5 1 Screen Layout 1 10 1 5 2 Basic Operatio...

Page 16: ...is repeated automatically The user can switch the measurement method This option measures traffic for the following three types of network topologies Note In this manual the user flow from client to...

Page 17: ...1 1 2 Network topology consisting of PPPoE client and Internet server Network topology consisting of Ethernet client and Internet server Traffic is measured by exchanging user data between the etherne...

Page 18: ...ing of multiple sessions Measures traffic and displays measured results while sessions established Real time display of information during traffic measurement Visual and easy to understand charts Save...

Page 19: ...rement function is disabled In addition remote control using the remote command options is also disabled The main unit can control the MU120121A 22A modules Other modules cannot be controlled by the m...

Page 20: ...again since the setting is retained in the main unit The PPPoE mode is set as follows Setting PPPoE mode 1 Connect a mouse to the main unit before turning it on Install the module to be used by this o...

Page 21: ...s changed the Exit button is enabled Press the Exit button to terminate the Setup utility Notes 1 Only one module can be used in PPPoE mode The module to be used is displayed with highlighted solid ch...

Page 22: ...tor is as shown in the Fig 1 4 3 The PPPoE application button on the top has changed to the dedicated button for starting this option Clicking this button opens this option screen from which user can...

Page 23: ...and press the Connect button The PPPoE Application main screen opens Select Automatically connect next time at the bottom of the screen to connect automatically and display the main screen next time...

Page 24: ...mended order of operation 1 5 1 Screen Layout This is the main screen of this option Parameter setting for traffic measurement execution of measurement and display of measured result can be all perfor...

Page 25: ...in a hierarchy Display the screen of the selected menu item in 3 Client Window Enable changing of 2 Window Bar width with the mouse 3 Client Window Display the setting monitoring and result view scre...

Page 26: ...Perform measurement from the Control Bar or Main menu Select the Results from the Window Bar or Main menu and open the Monitor or Results view screen in the Client Window Fig 1 5 2 1 Basic operation o...

Page 27: ...ysical interface parameters of each port b Port Pair Set the client server port pairs and set the protocol type c General Set the PAD interval for each port delay measurement during traffic measuremen...

Page 28: ...ions can be specified For details refer to Section 3 Measurement 3 Result view Displays the measured results during and after measurement For details refer to Section 4 Monitor Results a PPPoE Detail...

Page 29: ...file cannot be edited For detail refer to Section 2 4 Saving and Loading Settings b Import export information in Sessions The exported file can be edited For details refer to Section 2 4 Saving and Lo...

Page 30: ...it cannot be used when using this option Multi user function and remote control RS 232C interface connection GPIB interface connection Ethernet interface connection Note For the details of each functi...

Page 31: ...s 2 3 2 2 1 Physical 2 3 2 2 2 Port Pair Combination 2 5 2 3 Port Pair Parameters 2 7 2 3 1 General 2 7 2 3 2 Sessions 2 11 2 3 3 Node 2 16 2 4 Saving and Loading Settings 2 33 2 4 1 Saving and Loadin...

Page 32: ...erval user flow transmission time etc User Flow Port Pair Connection Port Pair Session Counter Setting Port Pair Sessions Server and client connection of Session and Rate of User Flow Port Pair Users...

Page 33: ...2 2 Ports Parameters 2 3 2 Settings 2 2 Ports Parameters 2 2 1 Physical Set the communication speed and method for each port Fig 2 2 1 1 Physical window...

Page 34: ...0 Mbps Full Duplex 100 Mbps Half Duplex 100 Mbps Full Duplex 1000 Mbps Full Duplex If Auto Negotiation is Off select one of the following 10 Mbps Half Duplex 10 Mbps Full Duplex 100 Mbps Half Duplex 1...

Page 35: ...the connection between client and server that is applied to the port connected to client Initial value Port Pair A PPPoE Port Pair B Ethernet Client Port Number Port 1 to 4 Set port number of the por...

Page 36: ...Section 2 Settings 2 6 Note Port 1 to 3 can be selected for Port Pair A and Port 2 to 4 can be selected for Port Pair B...

Page 37: ...ection 2 2 2 Port Pair Combination 2 3 1 General For Port pairs A and B set the delay distribution measurement range protocol packet transmission interval and user flow transmission time 1 Delay Set t...

Page 38: ...ckbox when using the same resolution and start point for UpLink and DownLink UpLink DownLink Press the UpLink or DownLink button to specify the link direction when Use same setting for UpLink DownLink...

Page 39: ...2 Port Pair Combination Fig 2 3 1 2 PAD Interval tab of the General window Table 2 3 1 2 Parameter setting on the PAD Interval tab of the General window Setting Item and Parameter Description PADI In...

Page 40: ...3 Parameter setting on the User Flow tab of the General window Setting Item and Parameter Description Continuous 1 to 9 999 999 ms 1 to 999 999 999 frames session Set the user flow transmission with t...

Page 41: ...ected to a server By default Client 1 and Server 1 are connected while others are disconnected When a line is connected clicking erases the line and cancels the session group When Client or Server set...

Page 42: ...r Setting 4 When this button is pressed the screen for setting the session traffic rate is displayed For details refer to Section 2 3 2 3 of Sessions and Rate of User Flow Notes 1 A client can be conn...

Page 43: ...e session to monitor at each 1 Client Session group A maximum of 32 sessions can be selected for each Port Pair In addition the monitored traffic direction can be selected as 2 UpLink DownLink When th...

Page 44: ...Sessions window the of Sessions and Rate of User Flow dialog is displayed The of Sessions and Rate of User Flow dialog is used to set the traffic transmission rate of the user flow and number of sess...

Page 45: ...10 No Set whether or not to send traffic Select the checkbox 2 of server if DownLink or client if UpLink that sends the traffic Initial value All checked of Session 0 to 1000 sessions Total session of...

Page 46: ...Section 2 Settings 2 16 2 3 3 Node 1 Users When protocol type is PPPoE Set the name of client or server PPP authentication ID and passwords Fig 2 3 3 1 Users tab of the Node window PPPoE...

Page 47: ...word pair in the User ID Password MAC Address dialog next page This dialog can control 128 pairs for server and 1000 pairs for client User ID 0 to 251 characters This is displayed when the Type is Inc...

Page 48: ...MAC Address dialog for Client Fig 2 3 3 3 User ID Passwords dialog for Server Note The User ID and password pair and MAC address setting can be save read as individual session data For details refer t...

Page 49: ...ab of the Node window Ethernet Table 2 3 3 2 Parameter setting on the Users tab of the Node window Ethernet Setting Item and Parameter Description Client or Server 1 to 16 Select the client or server...

Page 50: ...3 3 3 Parameter setting on the Address tab of the Node window PPPoE client Setting Item and Parameter Description Static Increment Select the MAC address setting method Initial value Static MAC Addre...

Page 51: ...ble 2 3 3 4 Parameter setting on the Address tab of the Node window PPPoE server Setting Items and Parameters Description IP Address Set the IP address of the PPPoE server Initial value 0 0 0 0 MAC Ad...

Page 52: ...alue Static IP MAC Address When the displayed IP MAC Address setting method is Static a combination of the IP Address and MAC Address is set This dialog can control 1000 items via Gateway If the traff...

Page 53: ...3 3 6 Parameter setting on the Address tab of the Node window Ethernet server Setting Item and Parameter Description IP Address Set the IP address of the Ethernet server Initial value 0 0 0 0 MAC Add...

Page 54: ...Section 2 Settings 2 24 3 VLAN The following tabs are used to set VLAN Fig 2 3 3 9 VLAN tab of the Node window...

Page 55: ...the VLAN tag level None VLAN tag is not set Single VLAN tag is set for one level Double VLAN tag is set for two levels Initial value None Tag1 Tag2 If VLAN tag is Double select the desired tag TPID he...

Page 56: ...imes Specify the number of retries when establishing a PPPoE session Initial value 2 Retry Interval 1 to 30 s Specify the interval of retries when establishing a PPPoE session Initial value 3 s Servic...

Page 57: ...Uniq value can be saved to read from a file For details refer to section 2 4 3 Saving and Loading Host Uniq Information 3 The content of Host Uniq when actually sent is the set value with 4 bytes inf...

Page 58: ...ption Retry Count 0 to 10 times Specify the number of retries when establishing a PPPoE session Initial value 2 Retry Interval 1 to 30 s Specify the interval of retries when establishing a PPPoE sessi...

Page 59: ...Max Receive Unit Initial value 1492 bytes Authentication Rule None PAP CHAP Both Select the authentication Rule Initial value CHAP LCP Echo Interval 0 to 300 s Set the LCP Echo transmission interval...

Page 60: ...re sent according to the LCP Echo Interval setting In addition LCP ACK is returned upon receiving LCP Echo and the session is continued The decision to disconnect the session depends solely on the Ret...

Page 61: ...2 3 Port Pair Parameters 2 31 2 Settings 6 User Flow Set the content format of the user flow to be sent Fig 2 3 3 14 User Flow tab of the Node window...

Page 62: ...ted Initial value 0 Destination Port 0 to 65535 Set the TCP UDP destination port number of the user flow to be sent This is valid when TCP IPv4 or UDP IPv4 is selected Initial value 0 Window Size 0 to...

Page 63: ...t be able to load it back to the main unit 1 Saving All Settings Save the setting parameters as follows 1 Select File Save Settings at the Main menu The Save Setting Data dialog appears 2 Specify a fi...

Page 64: ...ect File Export at the Main menu The Export session information dialog appears 3 Enter a file name and click Save 2 Loading Session information Load session information as follows 1 Display the User I...

Page 65: ...Export Binary Data dialog is displayed 3 Enter a file name and click Save 2 Loading Host Uniq information Load Host Uniq information as follows 1 Display the Host Uniq dialog 2 When the Import button...

Page 66: ...Section 2 Ports 2 36...

Page 67: ...bes how to perform measurement with this option 3 1 Measurement 3 2 3 1 1 Auto measurement 3 2 3 1 2 Manual Measurement 3 4 3 2 Control Bar 3 5 3 3 Starting Measurement 3 7 3 3 1 Starting Auto Measure...

Page 68: ...measurement is performed automatically The Auto measurement sequence is as follows 1 Select Port Pair Click Use checkbox 2 Establish PPPoE session of all clients for which connection is set 3 Start u...

Page 69: ...tween port pair A and port pair B or UpLink and DownLink direction ends measurement when the one that takes longer ends Steps 2 to 5 are repeated when Repeat is specified for Auto measurement When use...

Page 70: ...surement sequence is as follows 1 Select Port Pair Click Use checkbox 2 Establish PPPoE session of all clients for which connection is set 3 User flow start button on the Control Bar 4 Start user flow...

Page 71: ...5 Session count indication Indicates the number of established set PPPoE sessions When protocol type of client is PPPoE 6 Server Client indication Indicates server or client 7 Port button Displays the...

Page 72: ...ation Indicates server or client 7 Port button Displays the Physical window of each port Refer to Section 2 2 1 Physical 8 Connection speed indication Indicates the connection speed and communication...

Page 73: ...radio button 3 Select the Use checkbox of the port pair to measure 4 Set the Repeat count as necessary 5 Click the Start button Measurement starts When measurement ends the screen returns to the stat...

Page 74: ...e port pair to measure 4 Click the Start button This changes to Stop button during measurement 5 Select the client and server to send the user flow 6 Click the user flow start button to send User flow...

Page 75: ...nt when protocol type is ethernet Ping is performed as follows Fig 3 4 1 Ping dialog 1 Select the transmission port 2 Select the client or server to send 3 Select session when client is selected in st...

Page 76: ...Section 3 Operation 3 10...

Page 77: ...play of measurement result in real time Monitors and after measurement Results 4 1 Monitor 4 2 4 1 1 PPPoE Session Status 4 2 4 1 2 Traffic Counter 4 4 4 1 3 Delay 4 7 4 1 4 PPPoE Detail 4 9 4 2 Resul...

Page 78: ...each client and displayed for all client 1 Table Fig 4 1 1 1 PPPoE Tab of the Monitors Table window Table 4 1 1 1 Items on the PPPoE Tab of the Monitors Table window Item Description of Session Set n...

Page 79: ...t of clients that can be displayed on the graph The number of sessions established for the client corresponding to checkbox selected is displayed on the graph in chronological order 2 Selecting 3D che...

Page 80: ...Rx Rate Receive rate bit per second This item is displayed when Current is selected Frame Loss Number of lost frames This item is displayed when Accumulated is selected and is enabled after measuremen...

Page 81: ...es Rx Frames Received frames Tx Rate bit s Transmission rate bit per second This item is displayed when Current is selected Rx Rate bit s Receive rate bit per second This item is displayed when Curren...

Page 82: ...ter tab of the Chart window 1 This part shows the measurement items that can be displayed on the graph When a measurement item checkbox is selected the corresponding measured value is displayed on the...

Page 83: ...Table Fig 4 1 3 1 Delay tab of the Monitors Table window Table 4 1 3 1 Display items on the Delay Tab of the Monitors Table window Item Description Min Minimum delay Max Maximum delay below Distribut...

Page 84: ...the measurement direction UpLink or DownLink to display 2 This part shows a list of clients that can be displayed on the graph When a client checkbox is selected the corresponding client s delay dist...

Page 85: ...es and errors are displayed for every PPPoE session When click each element client number session number IP address session ID and status are displayed Fig 4 1 4 1 PPPoE Detail window Note When the pr...

Page 86: ...urement completes the PPPoE protocol packet count is displayed Fig 4 2 1 1 Results window 1 Select the client or server to display 2 Select the data Tx or Rx to display Notes 1 If protocol type is Eth...

Page 87: ...s for each port pair Save the contents displayed on the Monitor window and Results window Save the measurement result to a csv file as follows 1 Select File Export Result Port Pair A or Select File Ex...

Page 88: ...Section 4 Monitor Result 4 12...

Page 89: ...Appendix App I Appendix Appendix A Specifications A 1 Appendix B Stream Format B 1 Appendix C Menu C 1...

Page 90: ...Appendix App II...

Page 91: ...Max 1000 session port pair This PPPoE server emulation can not connect with other real PPPoE client Authentication support PAP CHAP VLAN emulation Max 2 VLAN tag can be configured Reference RFC2516 PP...

Page 92: ...tion 100 ns to 100 ms Variation resolution 30 Range 0 to 3 s Display format Table or graph PPPoE packet counter PPPoE PADI PADO PADR PADS PADT LCP Configure Request Configure Ack Configure Nak Configu...

Page 93: ...traffic disconnect Manual Mode Start to connect Start stop to send traffic Stop to disconnect 6 Other functions Ping Save load configurations Export results CSV format 7 Restrictions Available I F mo...

Page 94: ...Appendix A Specifications A 4...

Page 95: ...FCS Source MAC Address Priority Priority Type IP Header Length Destination Port CFI CFI Code Type of Service Sequence Number VID VID SESSION ID Total Length Acknowledge ment Number Length Identificat...

Page 96: ...pe of Service Sequence Number VID VID Total Length Acknowledgem ent Number Identification Data offset Flags Control bit White Fixed parameter Fragment Offset Window Green Parameter different according...

Page 97: ...ation Port CFI CFI Code Type of Service Sequence Number VID VID SESSION ID Total Length Acknowledge ment Number Length Identification Data offset Flags Control bit White Fixed parameter Fragment Offse...

Page 98: ...pe of Service Sequence Number VID VID Total Length Acknowledgeme nt Number Identification Data offset Flags Control bit White Fixed parameter Fragment Offset Window Light Blue Parameter different acco...

Page 99: ...format file Initialize All Settings Restores All Settings to default Quit Ends this Option Table C 1 2 Edit menu Menu Item Description Copy Copies the selected string to the clipboard Cut Copies the...

Page 100: ...r restores it to the original Size 800 600 Displays the main window as 800 600 dots Table C 1 4 Window menu Menu Item Description Physical Turns Auto Negotiation On Off and sets communication speed an...

Page 101: ...DL Starts Port pair B DownLink direction user flow transmission at Manual measurement Port Pair A UL Stops Port pair A UpLink direction user flow transmission at Manual measurement Port Pair A DL Sto...

Page 102: ...Appendix C Menu C 4...