ANGELUS SANITARY CAN MACHINE COMPANY
SERVICE NOTICE
2 of 3
10/11/99-18059001
Model 140S and 180S Seamers
Cover Feed Systems
Procedures continued;
8. Remove fasteners from the Bearing Retainer and pull down from the Housing.
9. The measurement taken earlier placed the Cap Pusher even with the Rail. Precision
machine the bottom of the Bearing Retainer to remove .015 material (,38mm). Hold a
tolerance of -.000/+.002. (,000/,05mm). Ensure that the top flange of the Retainer is
held parallel within .001 of an inch (,025mm) of the bottom surface.
10. Reinstall components in reverse order.
Removal of this material will raise the Feed Turret height placing Cap Pushers properly
above the Inner Cap guide rail top surface. Feed turret clearance between the Feed Turret
Plate and Inner Cap Guide should be maintained between .015 and .025 of an inch (,38 to
,635mm) clearance at the closest point even after machining the Bearing Retainer.
NOTE:
See the Feed Turret installation fixture on the next page.
Bearing Retainer
Gassing Manifold
w/Manifold Ring
Assembly and
Compression Springs
Feed Turret Assembly
Cap Feed Turret Screw
and Ball Bearing
Feed Turret Hub
Separator Drive Shaft