18043001
180S DISCHARGE TABLE PROCEDURES
DISCHARGE TABLE BREAKDOWN
1.
Raise Seamer to 26 inches between Upper Turret Housing & Base surface:
A.
Remove two M12 Hex. Head screws
from the Cap Guide Section Outer
Two M16 Hub Clamp Bolts
Collar Inserts. Inserts conceal two M16
Upper Turret Hub Clamp bolts. Inserts
are located at stations 3 and 17.
16S853 =
Cap Guide Section Outer Collar
4S841 =
Upper Turret Hub Clamp
B.
Loosen all four M10 X 16mm L. Hex.
Hd. Screws holding the Upper Turret
Hub Seal Clamp in place and the one M12
X 85mm Screw in the 71S817 Clamp. This
will reduce seal damage created within
splines.
31S817 =
Upper Turret Hub Seal Clamp
Cap Guide Sec. Collar Inserts
13S815 = Upper Turret Hub Seal
71S817 = Clamp
71S817 Clamp
C.
Locate the Upper Turret Hub Clamp
Screws (two M16 X 120mm L. Soc. Hd.
Screws) now exposed and loosen both.
Upper Turret Hub Seal Clamp
w/four M10 screws