26
10.3. Setting Threshold Values (of Limits and Ranks)
Step 1 While pressing and holding the SET key, press the COMP key to enter the comparator value
setting mode.
Step 2 Input a parameter for the comparison method using the numerical keys of 0 to 9 .
SET
:
Key to alternate between
+
/
-,
ENTER
:
Key to store and proceed, C
:
Cancel key
Step 3 When settings of threshold values (of limits and ranks) are finished,
is displayed.
(At this time, power-on-zero is not performed.)
Five-Level Comparator Mode
Three-Level Comparator Mode
(Upper and lower limit mode)
Seven-Level Comparator Mode
(Ranking Mode)
Example
:
HW-60KC-WP
LOLO
8.500 kg
LO
10.000 kg
HI
10.500 kg
HIHI
12.000 kg
Example
:
HV-200KC-WP
LO
148.85 kg
HI
152.50 kg
Example
:
HV-15KC-WP
Rank 1 (LOLO) 0.500 kg or more
Rank 2 (LO)
1.000 kg or more
Rank 3 (OK)
1.500 kg to 2.000 kg
Rank 4 (HI)
up to 2.500 kg
Rank 5 (HIHI)
up to 3.000 kg
Weighing
mode
Input the
LOLO limit
value
Input the
LO limit
value
Input the
HI limit
value
Input the
HIHI limit
value
Weighing
mode
Weighing
mode
Input the
LO limit
value
Input the
HI limit
value
Weighing
mode
Weighing mode
Input the threshold
value of rank 1
Input the threshold
value of rank 2
Input the lower
threshold value of
rank 3
Input the upper
threshold value of
rank 3
Input the threshold
value of rank 4
Input the threshold
value of rank 5
Weighing mode
The HV-CWP models change the position of the
readability depending on the weighing range. Regard
the hidden minimum digit as "0". The HV-CWP models
are as follows
:
HV-15KCWP, HV-60KCWP,
HV-200KCWP.