77
7.3.16 Control management
Auto Calibrate
Click on start to launch an auto calibration of colors, on your analog input/output chips.
(See chapter:
11.
Maintenance and support
)
Erase memories
Into this section, you can erase individual settings.
• Erase input settings memory: All input settings will return to
their default value. This includes image, aspect, user format
and keying parameters.
• Erase preset memories: All preset memories will return to
their default value.
• Erase monitoring layout memories: all saved monitoring
layout configuration will be erased, the monitoring layout will
be the default one.
• Erase library logos: All saved logos and frames will be deleted
from the library that can contain up to 100 still pictures.
• Erase library EDIDS: All EDIDs saved on the library free slots
will be deleted.
• Erase library sequencer: all sequences saved on the sequencer
library will be deleted.
Please note that a second click on
Start
is required in order to confirm the erase.
Factory reset
Configuration default value:
click on
START
(two times) to reset all standard parameters of
your device to default settings.
• This setting does not reset the network/link
settings.
• Library frames and logos will not be erased,
the device will reboot after this operation.
Factory Reset (Out of the Box):
click on
START
(two times) to reset all use parameters of your
device to default. After rebooting, you will find
your unit in the same state as when you opened
the box for the first time.
• This operation will reset the network and link settings.
• This operation will erase all libraries including the frames and logos library images.
• The device will reboot after this operation.
• This operation can also be found in the front panel.
NOTE:
If your device has trouble initializing, press and hold the
ENTER+EXIT
front panel keys during initiali
-
zation in order to start-up the device in factory fail-save mode. This mode will allow you to export a backup
file of your device that you can then send to
Technical Support
for inspection. Proceed to reset your device
as-is out of the box with
Factory Reset
.
Summary of Contents for ASC1602-4K