Using the DXP-PRO Wizard
34
DXP-PRO v1.1 - Programmer’s Guide
7.
For an indirect connection type, select
AXlink
for the Control Method.
Click the down-arrow adjacent to the Control Logic field.
Select from the list of indirect camera control options: AMX AXB-PT w/servo zoom or
AMX AXB-PT w/serial zoom. The selected choice is dependent on both the camera
controller and the mounted camera.
Use of an externally located serial interface is not available when this form of
indirect communication is selected.
If you want to use Macros, place a checkmark within the
Use Macro for Menu
Navigation and Device Routing
radio box.
If the Power Control tab becomes available (camera specific), select whether you want
the System to constantly monitor power to the device (through the
Govern Power
radio
box) or the device to provide power state information (via the
Device/Power Feedback
radio box).
Select the Power Sensing Method (if available).
8.
Click
OK
to complete the development of the new camera device.
9.
From the
System Information
dialog, click the
Add
button to add a Video Conference device to
the list via the
Device Configuration
dialog page.
10.
From the Source Type field of the Device Data tab, click the Source Type down-arrow to open
a drop-down list of available device types and select
Video Conference
.
11.
Enter a unique name for this video conferencing unit within the
Display Name
field.
12.
Select whether the Control Method is either
Serial
(RS-232) or
IP
. An IP Control Method
allows you to enter information into the IP Data field relating to the location of the target
conferencing unit. Both types of Control Methods require that you use the down-arrow to
select an associated Control Logic for the conferencing unit.
13.
If you want to use Macros, place a checkmark within the
Use Macro for Menu Navigation
and Device Routing
radio box.
14.
From the Camera Control section, use the down-arrows to select a Primary and/or Secondary
Camera used by the conferencing unit. If an IP Control Method was previously selected, the IP
Data field now becomes user-editable and can have any IP Address entered within it.
15.
Click
OK
to enter the information and return to the
System Information
dialog page.
How to configure G4 Computer Control (G4CC)
When using G4 Computer Control, it is important to understand that the DXP-PRO application
does not setup the stick applications for you. It is necessary to configure the corresponding
configCC
and
amxCC
application information fields (regarding the Master and touch panels) prior
to compiling the DXP-PRO project.
Any Master code alterations and configCC field entries must
be done prior to launching the amxCC executable.