8.0.4 Ex ter nal charg ing
•
Read and fol low man ual of the charger man u fac turer.
•
Check elec tro lyte level be fore charg ing and bal ance it where
nec es sary (see point 8.0.5 – main te nance)
•
Only charge the bat tery with suit able, volt age reg u lated charg -
ers with the same nom i nal volt age, oth er wise the bat tery has
to be dis con nected/re moved. Rec om men da tion:
Charg ing cur rent: 1/10 Am pere of the bat tery ca pac ity Ah
Charg ing volt age: 14,4 V
•
Never charge frozen bat ter ies or bat ter ies with a tem per a ture
higher than 45°C.
•
Con nect the pos i tive ter mi nal (+) of the bat tery with the pos i -
tive ter mi nal (+) of the charger and the neg a tive ter mi nal (-) of
the bat tery with the neg a tive ter mi nal (-) of the charger.
•
Only switch on the charger af ter con nect ing it to the bat tery.
•
Only switch off the charger af ter charg
ing has been com -
pleted.
•
In ter rupt charg ing if the acid tem per a ture ex ceeds 55°C.
•
In case the bat tery be comes hot or acid leaks, the charg ing
must be in ter rupted!
•
The bat tery is fully charged if:
•
Cur rent and volt age re main con stant with volt age reg u lated
charg ers.
•
The charg ing volt age does not rise any
more within two
hours with a cur
rent reg
u
lated charger. The au
to
matic
charger switches off or switches over to main tain charge.
•
En sure good ven ti la tion dur ing charg ing.
8.0.5 Main te nance
•
Keep the bat tery sur face clean and dry, only clean with damp
or antistatic cloth.
•
Pro tect ter mi nals/con nec tion clamps against cor ro sion (as
de scribed un der point 8.0.3).
•
Con trol elec tro lyte level (re gard in ner or outer mark ing on the
box or op ti cal acid level in di ca tor in the lid).
•
If nec es sary, re fill de min er al ised or dis tilled wa ter ac cord ing to
DIN IEC 60933-3… up to the max i mum acid level (never re fill
acid, for eign mat ters or so-called optimizers).
•
In case of high elec tro lyte loss, con sult a ga rage.
•
In case of in suf fi cient start ing per for mance, check bat tery and
pos si bly re charge it (see point 8.0.4).
8.0.6 Jump Start ing
•
Only use stan dard ized jump start ca bles (e.g. ac cord ing to
DIN 72 553).
•
Re gard in struc tions of the jump start ca ble man u fac turer.
•
Only use bat ter ies of the same nom i nal volt age.
•
Switch off the en gine of the giv ing ve hi cle (1).
•
Con nect the jumper ca ble to the pos i tive ter mi nal (+) of the do -
nor bat tery
and to the jump start con nec tion point (+)
of
the vi bra tion plate.
•
Only then clamp the jumper ca ble to the neg a tive ter mi nal (-)
of the do nor bat tery
and to a sta ble, bare mass on the vi bra -
tion plate
(do not use the neg a tive ter mi nal of the re ceiver
bat tery as a con nec tion point).
•
Start re ceiv ing ve hi cle (2).
•
In case the first at tempt to jump start the ve hi cle fails, the do -
nat ing ve hi cle can be started BEFORE the sec ond jump start
try.
•
Dis con nect the jump start ca bles in op po site or der.
8. Ba tte ry
76
12 V
12 V
1
2
B0001002.cdr
Summary of Contents for APH 110-95
Page 2: ......
Page 3: ...Originalbetriebsanleitung DE Book ID 2 00002027 APH 110 95 Serial Nr 0000001...
Page 44: ......
Page 46: ......
Page 84: ......
Page 85: ...Traduction du Mode d emploi original FR Book ID 2 00002027 APH 110 95 Serial Nr 0000001...
Page 86: ......
Page 124: ......
Page 126: ......
Page 164: ......
Page 165: ......