AMK Solac 11252 DeltaSol_BX.monen.ind
d
|
50
Level 5
Adjustment channels
Channel
Sub channel 1
Sub channel 2 Factory
setting
Change to
Description
Page
CMIN1
10 °C
Minimum collector temperature 1
OTCO1
OFF
Option tube collector function 1
TCST1
07:00
Tube collector starting time 1
TCEN1
19:00
Tube collector ending time 1
TCRU1
30 s
Tube collector runtime 1
TCIN1
30 min
Tube collector standstill interval 1
OCFR
OFF
Option collector frost protection
CFR O
4 °C
Antifreeze temperature collector on
CFR F
5 °C
Antifreeze temperature collector off
FRPST
1
Antifreeze store selection
COL 2 >
Collector 2
CEM2
115 °C
Collector emergency temperature 2
OCCO2**
OFF
Option collector cooling 2
CMAX2
95 °C
Maximum collector temperature 2
OCMI2
OFF
Option collector minimum limitation 2
CMIN2
10 °C
Minimum collector temperature 2
OTCO2
OFF
Option tube collector function 2
TCST2
07:00
Tube collector starting time 2
TCEN2
19:00
Tube collector ending time 2
TCRU2
30 s
Tube collector runtime 2
TCIN2
30 min
Tube collector standstill interval 2
LLOGI >
Loading logic
OOVRU*
OFF
Overrun option
COOL >
Cooling functions
OSYC**
OFF
System cooling
OSTC
OFF
Store cooling
OHDP**
OFF
Heat dump
DT3 >
Return preheating
DT3O
6 K
Switch-on difference
DT3F
4 K
Switch-off difference
S2DT3
3
Reference sensor heat source
AH >
Afterheating option
AH O
40 °C
Afterheating switch-on temperature
AH F
45 °C
Afterheating switch-off temperature
t1O
06:00
Switch-on time 1
t1F
22:00
Switch-off time 1
t2O
00:00
Switch-on time 2
t2F
00:00
Switch-off time 2
t3O
00:00
Switch-on time 3
t3F
00:00
Switch-off time 3
PUMP >
Pump speed
PUMP1
PULS
Speed variant pump 1
PUMP2
OnOF
Speed variant pump 2
PUMP3
OnOF
Speed variant pump 3
MAN >
Manual mode
MAN1
Auto
Manual mode 1
MAN2
Auto
Manual mode 2
MAN3
Auto
Manual mode 3
MAN4
Auto
Manual mode 4
BLPR >
OFF
Blocking protection
OTDIS >
OFF
Thermal disinfection option
OPARR >
OFF
Parallel relay option
OHQM >
OFF
Heat quantity measurement option
GFDS >
OFF
Registration Grundfos sensors
PRS* >
OFF
Pressure monitoring option
DATE>
Enter date
LANG >
En
Language
UNIT >
°C
Unit
OSDC >
SD card option
CODE
0000
User code
RESET
OFF
Factory setting
* This channel is only available if the Grundfos sensors have been registered in the
GFDS
channel.
** are blocked against each other