Channels
Channel
Sub channel 1
Sub channel 2 Factory
setting
Change to
Description
Page
ARR
Arrangement
LLOGI >
Loading logic
ODB >
Drainback option
tDTO
60 s
Time period - switch-on condition
tFLL
5 min
Filling time
tSTB
2 min
Stabilisation
OBST
OFF
Booster function
OOVRU*
OFF
Overrun option
DTOVR
5 K
Overrun
COOL >
Cooling functions
OSYC**
OFF
System cooling
DTCO
20 K
Switch-on difference system cooling
DTCF
15 K
Switch-off difference system cooling
OSTC
OFF
Store cooling
OHDP**
OFF
Heat dump
OTCL
110 °C
Overtemperature collector
OTPUM
OFF
Pump or valve logic
PUMP >
Pump speed
PUMP1
OnOF
Speed variant pump 1
n1LO
30 %
Minimum speed
n1HI
100 %
Maximum speed
PUMP2
OnOF
Speed variant pump 2
n2LO
30 %
Minimum speed
n2HI
100
Maximum speed
PUMP3
OnOF
Speed variant pump 3
n3LO
30 %
Minimum speed
n3HI
100%
Maximum speed
OTDIS >
Thermal disinfection option
PDIS
01:00
Monitoring period (interval)
DDIS
01:00
Heating period (duration of disinfection)
TDIS
60 °C
Disinfection temperature
SDIS
00:00
Starting time
TSDIS
3
Temperature sensor for disinfection
OTDIS
ON
Deactivation Thermal disinfection
OPARR >
Parallel relay option
PARRE
2
Parallel relay
INVER
OFF
Inversion
OHQM >
Heat quantity measurement option
FTYPE
1
Flow rate detection type
FMAX
6 l/min
Adjustable maximum flow rate
FIMP
1 l/lmp
Pulse rate
MEDT
3
Antifreeze type
MED%
40
Antifreeze concentration
SFHQM
1
Sensor flow HQM
SRHQM
4
Sensor return HQM
GFDS >
Registration Grundfos sensors
VFS
OFF
Range of flow rate sensor
RPS
OFF
Range of pressure sensor
OFLOW
OFF
Flow rate monitoring option
6.3
Overview of options and their
parameters
In the following, the additional options and parameters are
listed.
The options and parameters displayed depend on the sy-
stem as well as on the options and functions which have
been selected. Some of the options and parameters will
only be displayed, if they are available with the individual
adjustments.