If a malfunction occurs, a message will appear on the
display of the controller.
Directional pad flashes red. The symbol
is indicates
on the display and the symbol
flashes.
Sensor fault An error code instead of
a temperature is shown on the sensor
display channel.
- 88.8
888.8
Cable is broken
Check the cable.
S h o r t c i r c u i t .
Check the cable.
Disconnected PT1000 temperature sen-
sors can be checked with an ohmmeter.
Please check the resistance values corre-
spond with the table.
resistance values of
PT1000-sensors
The controller is protected by a fuse. The fuse holder (which
also holds the spare fuse) becomes accessible when the
cover is removed. To replace the fuse, pull the fuse holder
from the base.
fuse
WARNING!
Electric shock!
Upon opening the housing, live parts
are exposed.
Î
Always disconnect the control-
ler from power supply before
opening the housing!
The display is permanently off.
Press button
5
. Display illuminated?
no
Check the power supply of the controller. Is it discon-
nected?
The fuse of the controller
could be blown. The fuse
holder (which holds the
spare fuse) becomes ac-
cessible when the cover
is removed. The fuse can
then be replaced.
Controller has been in
standby, everything o.k.
Check the supply line and
reconnect it.
yes
yes
no