1-72
S100
Revised 10/2005
e-mail: [email protected] ; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
H - DOCUMENTATION
1. E L E C T R I C A L W I R I N G D I A G R A M S
WA R N I N G !
If the machine is not used with standard table, it is necessary to keep the connection,
which correspond to safety precaution of the country, which is pursued in.
Standard table has motor 1425/1725 rotation a minute (50/60 Hz) 550 W. After machine connection is
necessary to ensure electrical power supply of the machine in every fuse by the thermal fuse 10 A.
Electrical wiring of the table is supplied for following connection of the motor, needed diagrams of the
connection are mentioned below:
1. Connection 1N+PE 115V/60 HZ
2. Connection 1N+PE 230V/50 Hz
3. Connection 3N+PE 400V/50 Hz
4. Connection 3N+PE 230V/60 Hz
C A U T I O N !
It is necessary, to connect the conductive construction elements according to the diagram,
protection from dangerous touch realized according to EN 60204-1. The original table delivery includes all
required parts.