D - MACHINE ADJUSTMENT
Rotate the right-hand wheel until the needle bar reaches the lowest point of the first needle bar stroke 3,3
mm (0.130”). The correct adjustment allow enclosed gauge located on the support. The point of the left-
hand looper must be half way across the needle. Needle bar must lean on the highest point of gauge. Now it
is necessary to loosen the screws and move the left-hand looper to the right or left, to bring the
looper into the needle center line.
Tighten the screws .
Side view
Align the end of left looper with
the center of the needle
The highest gauge point
Lowest point
Gauge
N o t e :
Repeating the above mentioned steps is usual for reaching of the correct adjustment.
C A U T I O N !
Using S 100 AMF Reece designed replacement parts, will ensure the best quality and
highest production possible. The part numbers are listed in the Parts Section of this manual.
3.3 mm
0.130”
Needle bar lowest position