24
NOTE
: The “SELECT REVERSE MODE” option will only display if Select Reverse is programmed in
Dryer Setup under Reverse Mode.
7) The dryer will now display “PRESS START”. Press the “ENTER/START” Key to start
the dryer. The L.E.D. display will read MANUAL DRYING CYCLE, __MINUTES
REMAIN.
NOTE:
The dryer can be stopped at any time by pressing the “CLEAR/STOP” Key. If the temperature
is above the Cool Down setpoint when the “CLEAR/STOP” is pressed, then it will go into a
Cool Down cycle. If the “CLEAR/STOP” key is pressed again at this point the cycle that was
in progress
will be cancelled
and returned to the “READY” state. If the temperature is below the
Cool Down set point. The cycle that was in progress
will be cancelled
, and go to Wrinkle Guard.
8) Once the programmed drying time has expired, the Phase 7 OPL microprocessor controller
(computer) will proceed into the Cool Down Cycle (Mode).
9) Once the COOL DOWN Cycle begins at the end of the heat cycle the L.E.D. display will read
COOL DOWN TEMP ___/___MINUTES REMAINING. At the end of the heat cycle the
dryer will shut off the heat, and continue the Fan and Tumbler until the Cool Down time, or
temperature is reached.
10)
Once the COOL DOWN cycle is completed the Phase 7 OPL microprocessor
controller (computer) will proceed into the Wrinkle Guard cycle. The Audio Alert tone will
sound (for amount set in Audio Alert ON time). The L.E.D. display will read “WRINKLE
GUARD”. The times are fixed at 2 minutes OFF, 2 minutes ON for a max time of 99 minutes.
These times are not programmable. During the ON time, the Blower (fan) and the basket (tumbler)
will start to rotate (without heat for 2 minutes). The Phase 7 OPL microprocessor controller
(computer) will repeat this process until the Maximum Wrinkle Guard On Time has expired (99
minutes). The L.E.D. display will then read “CYCLE DONE” and lockout the dryer functions
until the doors are opened. It will then return to “READY”.
NOTE
:
Mechanical functions of the dryer are not allowed during the ON time. The Blower (fan)
must be OFF to perform mechanical functions. However the “CLEAR/STOP” key may be
pressed at any time to end the Wrinkle Guard cycle. Mechanical functions of the dryer are
allowed during the OFF time.
B. OPERATING NOTES
1.
All mechanical functions on an Auto machine (Doors/Tilt) can only take place when the Blower (Fan)
is turned off. i.e., If the selector switch for opening the doors is selected while in a drying cycle, there
will be no action until the Blower (Fan) is turned off.
2.
On a Manual machine, the
Phase 7 OPL microprocessor controller (computer) will display a fault
condition and stop the cycle if the doors open or machine tilts in the middle of a cycle. (Blower still
on)
3.
The RPM of the tumbler can be displayed by pressing and holding the DOWN ARROW key while a
cycle is in progress. If cycle has not been started, the display will read CPU Board Voltage Value. (23
- 26 Volts is normal)