21
5)
Once the preprogrammed percentage of extraction (dryness level) is reached, the drying
cycle will end, and the Cool Down Cycle will begin.
6)
Once the COOL DOWN Cycle begins at the end of the heat cycle the L.E.D. display will
read COOL DOWN TEMP ___/___MINUTES REMAINING. At the end of the heat
cycle the dryer will shut off the heat, and continue the Fan and Tumbler until the Cool
Down time, or temperature is reached.
7)
Once the COOL DOWN cycle is completed the Phase 7 OPL microprocessor
controller (computer) will proceed into the Wrinkle Guard cycle. The Audio Alert tone will
sound (for amount set in Audio Alert ON time). The L.E.D. display will read “WRINKLE
GUARD”. The times are fixed at 2 minutes OFF, 2 minutes ON for a max time of 99
minutes. These times are not programmable. During the ON time, the Blower (fan) and the
basket (tumbler) will start to rotate (without heat for 2 minutes). The Phase 7 OPL
microprocessor controller (computer) will repeat this process until the Maximum Wrinkle
Guard On Time has expired (99 minutes). The L.E.D. display will then read “CYCLE DONE”
and lockout the dryer functions until the doors are opened. It will then return to “READY”.
NOTE
:
Mechanical functions of the dryer are not allowed during the ON time. The Blower (fan)
must be OFF to perform mechanical functions. However the “CLEAR/STOP” key may be
pressed at any time to end the Wrinkle Guard cycle. Mechanical functions of the dryer are
allowed during the OFF time.
b.
Timed (Manual) Drying Cycle
1) L.E.D. display reads “READY” (no cycle in progress).
2) Press the letter on the keyboard (touchpad) corresponding to the cycle desired (i.e., Key
“D”).
NOTE
: (0-99) WILL REQUIRE THE “START/ENTER” KEY TO BE PRESSED AFTER THE
NUMBER IS SELECTED IN ORDER TO ACCEPT THE SELECTION AND START
DRYING.
3) The dryer will then start. (i.e, Blower, tumbler and heat)
4) The L.E.D. display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE
: Press the “UP ARROW” to view the tumbler temperature at any time.
NOTE:
The dryer can be stopped at any time by pressing the “CLEAR/STOP” Key. If the temperature
is above the Cool Down setpoint when the “CLEAR/STOP” is pressed, the dryer will go into a
Cool Down cycle. If the “CLEAR/STOP” key is pressed again at this point the cycle that was
in progress
will be cancelled
and returned to the “READY” state. If the temperature is below the
Cool Down set point. The cycle that was in progress
will be cancelled
, and go to Wrinkle Guard.
5) When the programmed drying time has expired, the Phase 7 OPL microprocessor controller
(computer) will proceed into the Cool Down Cycle (Mode).
6) Once the COOL DOWN Cycle begins at the end of the heat cycle the L.E.D. display will
read COOL DOWN TEMP ___/___MINUTE REMAINING. At the end of the heat cycle
the dryer will shut off the heat, and continue the Fan and Tumbler until the Cool Down time,
or temperature is reached.