58
OUTPUTS:
1.
R_HEAT – (GREEN LED)
This LED will indicate the status of the Rear Heat output. If the request
to turn on the Rear Heater is made, then the LED is On.
2.
ALERT – (GREEN LED)
This LED will indicate the status of the Horn output. If the request
to turn on the Horn is made, then the LED is On.
3.
FWD – (GREEN LED)
This LED will indicate the status of the Tumbler Forward direction
output. If the request to tumble the drum in the Forward direction is made, then the
LED is On.
4.
REV – (GREEN LED)
This LED will indicate the status of the Tumbler Reverse direction
output. If the request to tumble the drum in the Reverse direction is made, then the
LED is On.
5.
AIR JET – (GREEN LED)
This LED will indicate the status of the Air Jet output. If the request to
turn on the Air Jet is made, then the LED is On.
6.
FAN – (GREEN LED)
This LED will indicate the status of the Fan output. If the request to
turn on the Fan (Blower) is made, then the LED is On.
7.
F_HEAT – (GREEN LED)
This LED will indicate the status of the Front Heat output. If the
request to turn on the Front Heater is made, then the LED is On.
8.
AUX – (GREEN LED)
This is for a spare output to be programmed.
9.
PGR1 – (GREEN LED)
This is for a spare output to be programmed.
10. PGR2 – (GREEN LED)
This is for a spare output to be programmed.
11. PGR3 – (GREEN LED)
This is for a spare output to be programmed.
12. PGR4 – (GREEN LED)
This is for a spare output to be programmed.
13. OCL1 – (GREEN LED)
This LED will indicate the status of the Open Collector #1 output. If
the request to turn on the Open Collector #1 is made, then the LED is On. (Program-
mable and Defaulted to Front Door Open)
14. OCL2 – (GREEN LED)
This LED will indicate the status of the Open Collector #2 output. If
the request to turn on the Open Collector #2 is made, then the LED is On. (Program-
mable and Defaulted to Front Door Closed)
15. OCL3 – (GREEN LED)
This LED will indicate the status of the Open Collector #3 output. If
the request to turn on the Open Collector #3 is made, then the LED is On. (Program-
mable and Defaulted to Lint Drawer)
16. OCL4 – (GREEN LED)
This LED will indicate the status of the Open Collector #4 output. If
the request to turn on the Open Collector #4 is made, then the LED is On. (Program-
mable and Defaulted to Front Down)