17
2. REVERSE MODE -
This selection allows the operator to have a choice of Reverse or No Reverse
(single direction rotation) basket (tumbler) action in the manually loaded cycles
ONLY.
SELECT REVERSE - When this parameter (program) is chosen, the Phase 7 OPL microprocessor controller
(computer) will prompt the operator to decide whether or not the manually loaded
cycle entered is to be a reversing cycle.
ALWAYS REVERSE - In this operational mode the operator has no choice. Any manually loaded cycle
entered will be a reversing cycle.
3. ENTER “A” FACTOR 1 TO 9 - This parameter (program) is one of the factors that the Phase 7
OPL microprocessor controller (computer) uses when programmed in the Automatic Drying Cycle
(Mode)
(Patent No. 4,827,627)
. This factor pertains to the thermal characteristics of each model
dryer. In this Slope Program the Phase 7 OPL microprocessor controller (computer) monitors how
long it takes for the dryer to get to the selected temperature. The range of adjustment of this slope
factor is 1 through 9 in increments of one (1).
1)This slope factor has been programmed by the factory as outlined on
page 51
and
SHOULD NOT BE CHANGED
unless the Phase 7 OPL microprocessor controller
(computer) should fail and is being replaced. The replacement Phase 7 OPL
microprocessor controller (computer)
MUST BE PROGRAMMED
for the particular
dryer model and heating unit as shown in the “A” and “B” Factor table on
page 51
of
this manual.
4. ENTER “B” FACTOR 1 TO 99 - this parameter (program) is one of the factors that the Phase 7 OPL
microprocessor controller (computer) uses when programmed in the
Automatic Drying Cycle (Mode)
(Patent No. 4,827,627)
. This factor also pertains to the
thermal characteristics of each model dryer. This factor setting is dependent upon the model
dryer and the type of heating unit. The range of adjustment of this slope factor is 1 through
99 in increments of one (1).
1) This factor (Factor “B”) has been programmed by the factory as outlined on
page 51
and
SHOULD NOT BE CHANGED
unless the Phase 7 OPL microprocessor
controller (computer) should fail and is being replaced. The replacement Phase 7 OPL
microprocessor controller (computer)
MUST BE PROGRAMMED
for the particular
dryer model and heating unit as shown in the “A” and “B” Factor table on
page 51
of this
manual.
5. ENTER LINT COUNT 1 TO 5 - This selection sets the maximum amount of cycles it will run before
being locked out (out of service). The operator will be prompted to clean the lint drawer to continue
drying.
NOTE:
A minimum of 15 seconds is required to have the Lint Drawer opened in order to return to the
“READY” state once it is closed.