Input Data Format
ADVANCED MICRO CONTROLS INC.
6
86
Data Attribute 18: Die Monitor Data
Figure 6.13 Die Monitor Data Format (Data Attribute 18)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
1
0
0
1
0
1
1
Machine Position
2
2
State of Fault Outputs
(Bit 0 = Output 1 ... Bit 15 = Output 16)
Bit equals ‘0’ if the output is not assigned as a D.P. Fault Output.
Bit equals ‘1’ if the output is a D.P. Fault Output and a fault has not
occurred.
Bit equals ‘0’ if the output is a D.P. Fault Output and a fault has
occurred.
3
3
State of Fault Inputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
Bit equals ‘0’ if the input is not assigned as a D.P. Input.
Bit shows actual state of the input if it is assigned as a D.P. Input.
4
4
First Input to Fault
(Bit 0 = Input 1 ... Bit 15 = Input 16)
Bit equals ‘1’ if the associated input was the first to fault in the present
production cycle.
5
5
Faulted Die Protection Inputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
Bit equals ‘1’ if the associated input has a fault on it in the present
production cycle.
6
6
Selected Input Point Number
(See Word 3, Command Block 1, page 54.)
7
7
Number of Faults on the Selected Input
Die Protection Fault Counter value for the selected input.
8
8
Rising Position of Selected Input
Last position where the input made an inactive-to-active transition.
9
9
Falling Position of Selected Input
Last position where the input made an active-to-inactive transition.
10-19
10-19
Not Used
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...