20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Input Data Format
6
81
Data Attribute 6: Shift Register Setup Data
Figure 6.8 Shift Register Setup Data Format (Data Attribute 6)
Data Attribute 7: Production Cycle Setup Data
Figure 6.9 Production Cycle Setup Data Format (Data Attribute 7)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
0
0
1
1
0
1
1
Shift Register Input Number
If ‘0’, the shift register function is disabled
2
2
Shift Register FROM Setpoint
3
3
Shift Register TO Setpoint
4
4
Shift Position
5-19
5-19
Not Used
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackn
owledg
e
H
eartbeat
Hardware Fault
Resolve
r Fa
ult
Program Fault
Bits
RP
M C
la
m
p
ed
Out
put
Forced
0
0
0
1
1
1
1
1
Production Cycle Increment Position
2
2
Production Cycle Multiplier
3
3
Production Cycle Divisor
4-19
4-19
Not Used
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...