Output Data Format
ADVANCED MICRO CONTROLS INC.
5
72
Command Block 15: Save/Restore Program
This block allows you to save module programming to the internal memory of the ANS1. You can also use
this block to restore a program, which allows you to program the ANS1 on power up with a single command.
Figure 5.15 Command Block 15
Command Word Bits
Bit 5:
Delete All Programs.
Setting this bit to ‘1’ will delete all programs stored in the ANS1. Parameter
values of the active program will remain in RAM. If power is cycled before these parameters are
saved to a program, the ANS1 will power up with factory default settings.
Bit 8:
Load Program.
Setting this bit to ‘1’ will load the program into memory that is defined by word 1.
This bit and bit 9 cannot be set at the same time.
Bit 9:
Save Program.
Setting this bit to ‘1’ will save the present programming into the program that is
defined by word 1. This bit and bit 8 cannot be set at the same time.
Bit 10: Save Global Parameters.
Setting this bit to ‘1’ will save the Global Machine Configuration and
Brake Monitor Setup parameters to FLASH memory. The Global Machine Configuration parameters
are programmed using command block 2 as described starting on page 56 and the Brake Monitor
Setup parameters are programmed using command block 8 as described starting on page 67.
Word 1 Values
The FLASH memory used on the ANS1 is limited to 100,000 write cycles. Exceeding this
value may cause damage to the module.
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1024
T
ransmit Bit
0
0
0
0
Save Glob
al
Save P
rgm
Load Pr
gm
0
0
Delete Al
l
Clear Error
1
1
1
1
1
1025
Program Number to act on (Range of 0, 1-39, 40)
See description below
2-19
1026-1043
Not Used
Word 1 Value
Program
0
Active Program
When reading a program from memory, this block will have no effect.
When saving a program to memory, the last program read from memory
will be stored to.
1 - 39
Program Number
40
Factory Default
Used when reading a program only. This value will restore factory defaults for
all parameters in RAM.
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...