Input Data Format
ADVANCED MICRO CONTROLS INC.
6
84
Data Attribute 16: Machine Status Data (continued)
Figure 6.11 Machine Status Data Format (Data Attribute 16)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
15
15
RPM Enabled Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled because the machine speed is outside the programmed
speed range.
16
16
Time Expired Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
off because its programmed timer value has expired.
17
17
User Defined Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled because it is a user defined output that is in its disabled state.
(Start Time Overrun, Stop Time Overrun, Counter Overflow)
18
18
Selected Output Point Number
(See Word 2, Command Block 1, page 54)
19
19
Corrected Position of Selected Output
Present position used by the output. It is equal to the Machine
Position with the programmed Limit Switch Offset applied.
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...