Input Data Format
ADVANCED MICRO CONTROLS INC.
6
80
Data Attribute 4: Die Monitor Setup Data (continued)
Die Monitor Action Mode Values
.
Data Attribute 5: Brake Monitor Setup Data
Figure 6.7 Brake Monitor Setup Data Format (Data Attribute 5)
Action Mode
(Word 12 Value)
Result
0
Die Protection Fault Counter will continuously count.
Disable associated output when fault counter is non-zero.
1
Die Protection Fault Counter will reset to zero when cycle completes
without a die protection fault.
Disable associated output when fault counter is non-zero.
2
Die Protection Fault Counter will continuously count.
Associated output is disconnected from the monitor and is always active.
3
Die Protection Fault Counter will reset to zero when cycle completes
without a die protection fault.
Associated output is disconnected from the monitor and is always active.
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackn
owledg
e
He
artbe
at
Hardwa
re
Fa
ult
R
esolver Fault
Program Fault
Bits
RPM Clamped
Output Forc
ed
0
0
0
1
0
1
1
1
Brake Input Number
2
2
Complete Stop Count parameter
3
3
Start Time Limit parameter
4
4
Start Time Overrun Output (‘0’ if no output assigned to this function)
5
5
Stop Time Limit parameter
6
6
Stop Time Overrun Output (‘0’ if no output assigned to this function)
7-19
7-19
Not Used
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...