Output Data Format
ADVANCED MICRO CONTROLS INC.
5
68
Command Block 9: Program Shift Register Parameters
This block allows you to program the shift register parameters. An explanation of the Shift Register function
can be found in the
section of the manual starting on page 25.
1) This block only programs the shift register parameters.
on page 62 is used to program which shift register bit is used to control
an output.
2) If the Shift Register is disabled, all outputs that have a shift register bit assigned to them will
be disabled.
Figure 5.12 Command Block 9
Command Word Bits
Bit 5:
Delete All Shift Register Data.
Setting this bit to ‘1’ will delete all of the parameter values associated
with the Shift Register and disable it.
Bit 8:
Program Shift Register Parameters.
If this bit is reset to ‘0’ the shift register parameter are left at
their previous values. If this bit is set to ‘1’, words 1 through 4 are used to program the shift register
parameters.
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1024
T
ransmit Bit
0
0
0
0
0
0
Ap
ply
W
o
rd
s
1-4
0
0
Delete All
Clear Error
1
0
0
1
1
1025
Shift Register Input (Range of 0, 1 to 16)
If ‘0’, the shift register function is disabled
2
1026
Shift Register FROM setpoint (Range of 0 to (
Full Scale Count
-1))
3
1027
Shift Register TO setpoint (Range of 0 to (
Full Scale Count
-1))
4
1028
Shift Position (Range of 0 to (
Full Scale Count
-1))
5 - 19
1029-1043
Not Used
Summary of Contents for ANS1 ANYNET-I/O
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Page 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Page 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Page 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Page 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...