![Amazone UG 2200 Special Operating Manual Download Page 82](http://html1.mh-extra.com/html/amazone/ug-2200-special/ug-2200-special_operating-manual_2919780082.webp)
Structure and function
5.15
Spray liquid tank
The spray liquid tank is filled via
•
the filling opening,
•
the suction hose (optional) on the suction port,
•
the pressure filling connection (optional)
Fig. 44
(1) Spray liquid tank
(2) Internal cleaning
(3) Hinged/screw lid for filling opening
(4) External filling connection
(5) Filling sieve
(6) Float for determining the fill level
(7) Agitator
(8) Additional agitator (only UG Super)
WARNING
Damage to the lid and escaping spray agent when driving.
The filling sieve made of stainless steel as a surge protection must
always be mounted.
Hinged/screw lid for the filling opening
•
To open the lid, rotate to the left and swing open.
•
To close the lid, fold down and rotate to the right until tight.