![Amazone UG 2200 Special Operating Manual Download Page 180](http://html1.mh-extra.com/html/amazone/ug-2200-special/ug-2200-special_operating-manual_2919780180.webp)
Using the machine
10.8.1
Diluting the residue in the spray liquid tank and spraying the diluted residue
at the end of spraying operation
For machines with comfort equipment, see operating manual for soft-
ware ISOBUS.
1. Switch off the sprayer boom.
2. Move switch tap
F
to position
0
.
3. Move switch tap
E
to position
0
.
4. Move switch tap
D
to the
position.
5. Move switch tap
B
to the
position.
6. Move switch tap
A
to the
position.
7. Run the pump at approx. 400 rpm.
8. Dilute the residue in the spray liquid tank
with approx.
200
litres from the flushing wa-
ter tank.
Fig. 131
9. Move switch tap
A
to the
position.
10. Move switch tap
B
to the
position.
11. Move switch tap
D
to the
position.
12. Spray the diluted residue onto an
untreated
area
.
13. When the residue in the spray liquid tank
falls below 50 litres, switch agitator
C
and
G
(UG Super) to
0
.
14. Flush the bypass line and pressure relief by
switching spraying on and off five times.
•
Keep spraying switched off for at
least 10 seconds each time.
•
The spray pressure should be at
least 5 bar.
15.Repeat steps 3 to 14.
180