Using the machine
10.7
Spraying operation
Observe the separate operating manual for the operating terminal.
Special instructions for spraying operation
•
Test the field sprayer by carrying out calibration
ο
before the start of the season.
ο
in the case of deviations between the actual indicated spray
pressure and the spray pressure prescribed in the spray
table.
•
Before starting spraying, determine the exact spray rate re-
quired, referring to the instructions of the crop protection agent
manufacturer.
→
Before starting spraying, enter the required spray rate (target
rate) in control terminal/ AMASPRAY
+
.
•
During spraying operation, precisely adhere to the required
spray rate [l/ha]
ο
in order to achieve the best possible results from your crop
protection measure.
ο
to avoid unnecessary pollution of the environment.
•
Select the required nozzle type from the spray table before
spraying starts, taking account of
ο
the intended operational speed,
ο
the required spray rate and
ο
the required atomisation characteristic (fine, medium or
coarse-dropped) of the crop protection agent used for the
crop protection measure.
→
Refer to the section "Spray tables for flat-fan, anti-drift, injector
and airmix nozzles", Seite 239.
•
Select the required nozzle size from the spray table before
spraying starts, taking account of
ο
the intended operational speed,
ο
the required spray rate and
ο
the target spray pressure.
→
Refer to the section "Spray tables for flat-fan, anti-drift, injector
and airmix nozzles", Seite 239.
•
Select a low operational speed and a low spray pressure to pre-
vent wastage from drifting.
→
Refer to the section "Spray tables for flat-fan, anti-drift, injector
and airmix nozzles", Seite 239.
•
At wind speeds of 3 m/s, take additional drift reduction measures
(refer to the section "Measures for drift reduction", Seite 178.