![Amazone UG 2200 Special Operating Manual Download Page 143](http://html1.mh-extra.com/html/amazone/ug-2200-special/ug-2200-special_operating-manual_2919780143.webp)
Commissioning
7.6
Adjusting the hydraulic system with the system setting screw
Only with Profi folding:
•
Be sure to match the hydraulic systems of the tractor and the
implement.
•
The implement hydraulic system is adjusted using the system
setting screw on the hydraulic block of the implement.
•
Elevated hydraulic oil temperatures are the result of incorrect
adjustment of the system setting screw, caused by persistent
strain on the pressure relief valve of the tractor hydraulic system.
•
Adjustments may only be made in a pressureless state!
•
If there are hydraulic malfunctions between the tractor and the
implement during start-up, please contact your service partner.
(1) System setting screw can be adjusted in
position A and B
(2) LS connection for the load sensing control
line
Fig. 115
Implement-side connections in compliance with
ISO15657:
(1) P – feed line, pressure line, plug standard
width 20
(2) LS – control line, plug standard width 10
(3) T - return line, socket standard width 20
Fig. 116