Cleaning, maintenance and repairs
220
EDX 9000-TC BAH0048-6 09.2019
12.5.6 Checking the fertiliser coulter furrow former
The new furrow former must not
protrude too far beyond the edge of
the coulter disc. The worn furrow
formers can be individually replaced
up to a coulter disc diameter of 370
mm.
1. Loosen the nuts (Fig. 317/1) and remove
them.
2. Uninstall the worn furrow formers (Fig.
317/2).
3. Mount new furrow formers.
4. Fit on the nuts.
5. Adjust the gap between the furrow former
and coulter disc to 1-2 mm by tightening the
nuts differently.
6. Lock the nuts.
Fig. 317
12.5.7 Checking the wear bushing on the support roller arm
1. Check the condition of the wear bushing.
Replace the wear bushing in a timely
manner before the setting spindle damages
the support arm.
2. Loosen the bolt (Fig. 318/4) and remove it.
3. Dismount the support roller arm (Fig. 318/2)
with the support roller.
4. Remove the spot weld on the rear (Fig.
318/3).
5. Dismount the worn bushing (Fig. 318/1).
6. Insert a new bushing.
7. Place spot weld on the rear (Fig. 318/3).
8. Mount the support roller arm with the
support roller.
9. Fit on and tighten the bolt.
Fig. 318
Summary of Contents for EDX 9000-TC
Page 27: ...General Safety Instructions EDX 9000 TC BAH0048 6 09 2019 27 Fig 3 Fig 4...
Page 243: ...Hydraulic diagram EDX 9000 TC BAH0048 6 09 2019 243 Fig 346...
Page 244: ...Hydraulic diagram 244 EDX 9000 TC BAH0048 6 09 2019...
Page 245: ...Notes EDX 9000 TC BAH0048 6 09 2019 245 14 Notes Space for your notes...