Settings
EDX 9000-TC BAH0048-6 09.2019
141
8.1.11 Adjusting the carrier roller scraper
Carbide-coated scrapers (Fig. 183/1) clean the
carrier rollers.
The distance between the scraper and carrier
roller is 10 mm.
To adjust the scrapers, loosen the bolts (Fig.
183/2).
Fig. 183
8.1.12 Adjusting the press roller scraper
Seeding coulters with fine seed equipment have
a carbide-coated scraper (Fig. 184/3) to clean
the press rollers.
To adjust the scraper, loosen the fastening nut
(Fig. 184/1) and the adjustment nut (Fig. 184/2).
Swivel the holding arm on the press roller (Fig.
184/3).
The distance between the scraper and press
roller is 1 mm.
Fig. 184