Settings
EDX 9000-TC BAH0048-6 09.2019
151
8.2.6
Adjusting the furrow former on the fertiliser coulter
The gap (arrow) between the furrow former (Fig.
202/1) and coulter disc (Fig. 202/2) is adjustable.
Fig. 202
The furrow former (Fig. 202/1) should be close to
the coulter disc (Fig. 202/2), but not touch it.
The gap (arrow) can be adjusted, like a toggle,
by variously tightening the two bolts (Fig. 202/3).
Do not tighten the bolts too hard. It should be
possible to move the furrow former with average
force.
Lock the bolts after each adjustment.
8.3
Adjusting the track marker length and working intensity
DANGER
It is forbidden to stand in the swivelling area of the track marker!
1. Direct people out of the danger area.
2. Fold out both track markers simultaneously
on the field (see AMATRON 3 operating
manual) and drive several metres.
3. Disengage the tractor PTO shaft, engage
the tractor parking brake, shut off the
tractor engine and remove the ignition key.
4. Unscrew the bolt (Fig. 203/1).
5. Set the track marker length to distance "A"
(see section 8.3.1, Seite 152).
6. Release both bolts (Fig. 203/2).
7. Turn the track marker disc to adjust the
working intensity of the track marker so
that it runs roughly parallel to the direction
of travel on light soil and is more attuned to
grip on heavier soil.
8. Fully tighten all bolts.
9. The implement is equipped with two track
markers.
Repeat the procedure as described.
Fig. 203
Summary of Contents for EDX 9000-TC
Page 27: ...General Safety Instructions EDX 9000 TC BAH0048 6 09 2019 27 Fig 3 Fig 4...
Page 243: ...Hydraulic diagram EDX 9000 TC BAH0048 6 09 2019 243 Fig 346...
Page 244: ...Hydraulic diagram 244 EDX 9000 TC BAH0048 6 09 2019...
Page 245: ...Notes EDX 9000 TC BAH0048 6 09 2019 245 14 Notes Space for your notes...